Calculate conduction resistance through a flat homogeneous layer.
Calculator
How to use this calculator
Calculate conduction resistance through a flat homogeneous layer.
- Enter Area A (m²), Wall thickness L (m), Wall conductivity k (W/m·K). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Plane wall thermal resistance calculator
Calculate conduction resistance through a flat homogeneous layer.
Inputs and units
- Area A (m²): Heat-transfer surface area normal to the conduction direction, in m².
- Wall thickness L (m): Distance through the wall, in metres; do not substitute block height, which lies in the face plane.
- Wall conductivity k (W/m·K): Thermal conductivity k in W/(m·K); higher conductivity lowers the slab resistance.
Formula and method
R = L/(kA)
Worked example
A 0.05 m layer with k=0.8 W/(m·K) over 3 m² gives R=0.05/(0.8·3)=0.02083 K/W.
Interpreting the result
For a fixed temperature difference, higher resistance lowers conductive heat-transfer rate. Layer resistances in series can be added when interface assumptions fit.
Assumptions and limits
Thickness, area, and conductivity must be positive. Assumes steady one-dimensional conduction through uniform material; surface films, bridges, and contact resistance are excluded.
Sources and method
- Relates steady conduction through a slab to thickness, area, and conductivity; resistance form is the reciprocal proportionality. OpenStax University Physics Volume 2: mechanisms of heat transfer
Frequently asked questions
Which inputs determine this result?
The visible inputs are Area A (m²), Wall thickness L (m), Wall conductivity k (W/m·K). Each is used by the displayed formula; the calculator does not use any other hidden measurement.
When does this method apply?
Thickness, area, and conductivity must be positive. Assumes steady one-dimensional conduction through uniform material; surface films, bridges, and contact resistance are excluded.
How do I use the Plane wall thermal resistance calculator?
Enter Area A (m²), Wall thickness L (m), Wall conductivity k (W/m·K). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Plane wall thermal resistance?
A 0.05 m layer with k=0.8 W/(m·K) over 3 m² gives R=0.05/(0.8·3)=0.02083 K/W.
What does the Plane wall thermal resistance calculator calculate?
Calculate conduction resistance through a flat homogeneous layer.
See the calculation methodology.
Good calculators show their work.