How to use this calculator
Estimate uniform rectangular-fin efficiency and convection heat using a corrected-length tip approximation.
- Enter Fin width (mm), Fin thickness (mm), Fin length from base (mm), Fin conductivity (W/m/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Rectangular straight fin efficiency and heat explained
A straight rectangular fin loses heat along its sides and through its tip. The corrected-length approximation represents tip convection by a small extension of the fin, then compares its heat transfer with an isothermal fin at the base temperature.
Inputs, symbols, and units
w— Fin width (mm)- Positive rectangular cross-section width in millimeters; converted to meters.
t— Fin thickness (mm)- Positive cross-section thickness in millimeters, used with width to form area and perimeter.
l— Fin length from base (mm)- Physical exposed length from the fixed-temperature base to the tip, in millimeters.
k— Fin conductivity (W/m/K)- Uniform fin thermal conductivity in W/(m·K).
hc— Convection coefficient (W/m²/K)- Uniform convection coefficient over the modeled fin surface in W/(m²·K).
tb— Fin base temperature (°C)- Prescribed fin-base temperature in °C.
ta— Ambient temperature (°C)- Uniform surrounding-fluid temperature in °C; only the base-to-fluid difference drives heat transfer.
Formula and method
m=√(hP/kAc); corrected Lc=L+Ac/P; η=tanh(mLc)/(mLc)
Convert fin dimensions to metres, then form cross-sectional area Ac, exposed perimeter P, and corrected length L+Ac/P. The parameter m=sqrt(hP/(kAc)) controls the hyperbolic-tangent efficiency. Multiply efficiency by the corrected isothermal convection area and base-to-air temperature difference.
A worked scenario
Fin width (mm) = 50; Fin thickness (mm) = 2; Fin length from base (mm) = 30; Fin conductivity (W/m/K) = 200; Convection coefficient (W/m²/K) = 20; Fin base temperature (°C) = 80; Ambient temperature (°C) = 20.
- Corrected-length fin efficiency: 0.96804179
- Fin heat transfer: 3.74051348 W
- Corrected fin length: 0.03096154 m
The cross section is 0.0001 m² and its exposed perimeter is 0.104 m. Corrected length is 0.03+0.0001/0.104=0.03096154 m; efficiency is 0.96804179 and heat transfer is ηhPLc(80−20)≈3.74051348 W.
Assumptions and edge cases
One-dimensional conduction, uniform convection, fixed base temperature, and negligible radiation/contact resistance. Corrected length approximates tip convection.
Frequently asked questions
Does efficiency mean heat exceeds the no-fin case?
No, it compares actual fin heat with an isothermal fin at base temperature.
Why add Ac/P to length?
It approximates heat loss from the tip within an insulated-tip model.
Can heat be negative?
Yes, for a base colder than ambient.
How do I use the Rectangular straight fin efficiency and heat calculator?
Enter Fin width (mm), Fin thickness (mm), Fin length from base (mm), Fin conductivity (W/m/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Rectangular straight fin efficiency and heat?
Fin width (mm) = 50; Fin thickness (mm) = 2; Fin length from base (mm) = 30; Fin conductivity (W/m/K) = 200; Convection coefficient (W/m²/K) = 20; Fin base temperature (°C) = 80; Ambient temperature (°C) = 20. Corrected-length fin efficiency: 0.96804179 Fin heat transfer: 3.74051348 W Corrected fin length: 0.03096154 m The cross section is 0.0001 m² and its exposed perimeter is 0.104 m. Corrected length is 0.03+0.0001/0.104=0.03096154 m; efficiency is 0.96804179 and heat transfer is ηhPLc(80−20)≈3.74051348 W.
Read our calculation methodology.