CalcWorldHub
Free online calculator · no signup

Daily light integral (DLI) calculator

Convert average photosynthetic photon flux density and daily lighting hours into plant-usable light per day.

4,000 tools
Daily light integral (DLI) calculator — Average PPFD (µmol·m⁻²·s⁻¹), Lighting duration (hours per day) and calculation method
Daily light integral (DLI) calculator: inputs and calculation method.

How to use this calculator

Convert average photosynthetic photon flux density and daily lighting hours into plant-usable light per day.

  1. Enter Average PPFD (µmol·m⁻²·s⁻¹), Lighting duration (hours per day). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Agriculture calculation

How this calculation works

Daily light integral adds up photosynthetic photon flux over a full day. For a constant average PPFD during a lighting window, multiplying by seconds of exposure gives the total photon amount per square metre.

Inputs and units

ppfd — Average PPFD (µmol·m⁻²·s⁻¹)
Use photosynthetic photon flux density measured at the canopy.
hours — Lighting duration (hours per day)
Enter total daily exposure hours from 0 to 24.

Formula

Displayed formula

DLI (mol·m⁻²·day⁻¹) = average PPFD (µmol·m⁻²·s⁻¹) × lighting hours × 3,600 ÷ 1,000,000.

Method

Enter average PPFD at the plant canopy and hours of exposure in a 24-hour day. This constant-intensity estimate converts micromoles per second into moles per square metre per day.

Worked example

An average PPFD of 250 µmol·m⁻²·s⁻¹ over 16 hours gives 250 × 16 × 3,600 ÷ 1,000,000 = 14.4 mol·m⁻²·day⁻¹.

Assumptions and limits

The result assumes PPFD remains constant during the entered period. Real sunlight and fixtures vary through the day and across the canopy; sensor position, spectrum, and shading affect the measured value.

Frequently asked questions

Does DLI include darkness outside the lighting period?

The input totals the exposure within one day; periods with no measured light contribute zero photon dose.

Can I add sunlight and grow-light readings?

Yes, if you measure or estimate the combined canopy PPFD over time. A constant average is only an approximation.

Does DLI tell me the ideal light for every crop?

No. Crop, cultivar, growth stage, temperature, CO₂, and other conditions influence a suitable target.

How do I use the Daily light integral (DLI) calculator?

Enter Average PPFD (µmol·m⁻²·s⁻¹), Lighting duration (hours per day). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Daily light integral (DLI)?

An average PPFD of 250 µmol·m⁻²·s⁻¹ over 16 hours gives 250 × 16 × 3,600 ÷ 1,000,000 = 14.4 mol·m⁻²·day⁻¹.