How to use this calculator
Convert average photosynthetic photon flux density and daily lighting hours into plant-usable light per day.
- Enter Average PPFD (µmol·m⁻²·s⁻¹), Lighting duration (hours per day). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Daily light integral adds up photosynthetic photon flux over a full day. For a constant average PPFD during a lighting window, multiplying by seconds of exposure gives the total photon amount per square metre.
Inputs and units
ppfd— Average PPFD (µmol·m⁻²·s⁻¹)- Use photosynthetic photon flux density measured at the canopy.
hours— Lighting duration (hours per day)- Enter total daily exposure hours from 0 to 24.
Formula
DLI (mol·m⁻²·day⁻¹) = average PPFD (µmol·m⁻²·s⁻¹) × lighting hours × 3,600 ÷ 1,000,000.
Method
Enter average PPFD at the plant canopy and hours of exposure in a 24-hour day. This constant-intensity estimate converts micromoles per second into moles per square metre per day.
Worked example
An average PPFD of 250 µmol·m⁻²·s⁻¹ over 16 hours gives 250 × 16 × 3,600 ÷ 1,000,000 = 14.4 mol·m⁻²·day⁻¹.
Assumptions and limits
The result assumes PPFD remains constant during the entered period. Real sunlight and fixtures vary through the day and across the canopy; sensor position, spectrum, and shading affect the measured value.
Frequently asked questions
Does DLI include darkness outside the lighting period?
The input totals the exposure within one day; periods with no measured light contribute zero photon dose.
Can I add sunlight and grow-light readings?
Yes, if you measure or estimate the combined canopy PPFD over time. A constant average is only an approximation.
Does DLI tell me the ideal light for every crop?
No. Crop, cultivar, growth stage, temperature, CO₂, and other conditions influence a suitable target.
How do I use the Daily light integral (DLI) calculator?
Enter Average PPFD (µmol·m⁻²·s⁻¹), Lighting duration (hours per day). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Daily light integral (DLI)?
An average PPFD of 250 µmol·m⁻²·s⁻¹ over 16 hours gives 250 × 16 × 3,600 ÷ 1,000,000 = 14.4 mol·m⁻²·day⁻¹.
Reference: University of Minnesota Extension lighting guidance. See our calculation methodology.