How to use this calculator
Estimate CO₂ gas mass and ideal injection time to raise a well-mixed greenhouse air volume to a target concentration.
- Enter Greenhouse air volume (m³), Current CO₂ concentration (ppm), Target CO₂ concentration (ppm), Air temperature (°C), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Greenhouse carbon dioxide enrichment mass and injection time explained
Treat the ppm rise as a gas volume fraction and use the ideal-gas law at one atmosphere to estimate the additional CO₂ inventory before dividing by supply rate.
Inputs, symbols, and units
volume— Greenhouse air volume (m³)- Enclosed air volume receiving gas.
current— Current CO₂ concentration (ppm)- Measured starting concentration by volume.
target— Target CO₂ concentration (ppm)- Desired concentration by volume, above the starting value.
temp— Air temperature (°C)- Temperature for the ideal-gas conversion.
rate— CO₂ supply rate (kg/h)- Mass flow reaching the greenhouse enclosure.
Formula and method
Δm = V Δx P MCO₂ / (R T); ideal injection time = Δm / mass flow.
It divides the estimated CO₂ mass increase by the entered delivered mass flow in kg/h; it does not include ramping or mixing losses.
A worked scenario
Greenhouse air volume (m³) = 1200; Current CO₂ concentration (ppm) = 420; Target CO₂ concentration (ppm) = 900; Air temperature (°C) = 22; CO₂ supply rate (kg/h) = 3.
- Ideal CO₂ mass increase: 1.046679 kg
- Ideal injection time: 0.348893 h
- Concentration increase: 480 ppm
It assumes a well-mixed, sealed greenhouse at one atmosphere with no plant uptake, ventilation, leakage, or pressure change.
Assumptions and edge cases
No. Use a monitored control system and applicable safety limits; this ideal-gas inventory estimate is not a ventilation or worker-safety assessment.
Reading the outputs
The main result is greenhouse CO₂ mass increase; supporting outputs are labeled with their own units. Use the units shown beside each input and result.
Frequently asked questions
What conditions does the CO₂ mass estimate assume?
It assumes a well-mixed, sealed greenhouse at one atmosphere with no plant uptake, ventilation, leakage, or pressure change.
How does the injection-time result use supply rate?
It divides the estimated CO₂ mass increase by the entered delivered mass flow in kg/h; it does not include ramping or mixing losses.
Can this calculation set an occupational CO₂ limit?
No. Use a monitored control system and applicable safety limits; this ideal-gas inventory estimate is not a ventilation or worker-safety assessment.
How do I use the Greenhouse carbon dioxide enrichment mass and injection time calculator?
Enter Greenhouse air volume (m³), Current CO₂ concentration (ppm), Target CO₂ concentration (ppm), Air temperature (°C), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Greenhouse carbon dioxide enrichment mass and injection time?
Greenhouse air volume (m³) = 1200; Current CO₂ concentration (ppm) = 420; Target CO₂ concentration (ppm) = 900; Air temperature (°C) = 22; CO₂ supply rate (kg/h) = 3. Ideal CO₂ mass increase: 1.046679 kg Ideal injection time: 0.348893 h Concentration increase: 480 ppm It assumes a well-mixed, sealed greenhouse at one atmosphere with no plant uptake, ventilation, leakage, or pressure change.
Read our calculation methodology.