How to use this calculator
Estimate underdamped viscous damping from two same-sign peaks in a freely decaying vibration record.
- Enter Earlier same-sign peak amplitude, Later same-sign peak amplitude, Full cycles between peaks. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Damping from logarithmic decrement explained
Use Earlier same-sign peak amplitude with Later same-sign peak amplitude to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
Example with entered values
Earlier same-sign peak amplitude = 12; Later same-sign peak amplitude = 7; Full cycles between peaks = 4.
- Estimated damping ratio: 0.021441
- Logarithmic decrement per cycle: 0.134749
The inputs above are an illustrative scenario. Display values are rounded after the calculation.
The calculation behind the result
δ=ln(Aearly/Alate)/cycles; ζ=δ/√(4π²+δ²).
Inputs and units
- Earlier same-sign peak amplitude
- Peak magnitude measured from equilibrium.
- Later same-sign peak amplitude
- Later peak magnitude in the same units.
- Full cycles between peaks
- Number of oscillation periods separating the peaks.
Before interpreting the result
Requires free decay, an approximately linear underdamped mode, and amplitudes measured from equilibrium. Forced response and mixed modes invalidate the simple interpretation.
The coefficient-based damping tool starts from physical model parameters. Logarithmic decrement starts from an observed decay envelope.
Source and method reference
The tutorial estimates damping ratio from measured peaks using logarithmic decrement for an underdamped response. University of Michigan Control Tutorials for MATLAB and Simulink: Simple Pendulum.
Frequently asked questions
Can I use adjacent opposite-sign peaks?
Not with this full-cycle input convention.
Why measure from equilibrium?
A baseline offset distorts the amplitude ratio.
What if the peaks grow?
This decaying-response model is not appropriate.
How do I use the Damping from logarithmic decrement calculator?
Enter Earlier same-sign peak amplitude, Later same-sign peak amplitude, Full cycles between peaks. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Damping from logarithmic decrement?
Earlier same-sign peak amplitude = 12; Later same-sign peak amplitude = 7; Full cycles between peaks = 4. Estimated damping ratio: 0.021441 Logarithmic decrement per cycle: 0.134749 The inputs above are an illustrative scenario. Display values are rounded after the calculation.
See our calculation methodology.