How to use this calculator
Estimate time until one pixel reaches its entered usable charge limit.
- Enter Usable electron well capacity per pixel, Current electron charge per pixel, Peak pixel source rate (electrons/s), Other electron rate per pixel (electrons/s). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Detector saturation exposure time explained
Exposure time is the remaining usable charge headroom divided by the combined pixel electron rate. It assumes constant source and background rates and treats the entered well limit as the saturation threshold; blooming, nonlinearity, readout clipping, and cosmic-ray events are outside the estimate.
Inputs, symbols, and units
w— Usable electron well capacity per pixel- Usable electron well capacity per pixel.
i— Current electron charge per pixel- Current electron charge per pixel.
s— Peak pixel source rate (electrons/s)- Peak pixel source rate (electrons/s).
b— Other electron rate per pixel (electrons/s)- Other electron rate per pixel (electrons/s).
Formula and method
(w-i)/(s+b)
Symbols use the input definitions below. Constant pixel rates; blooming, nonlinear response, ADC clipping, and cosmic rays are excluded..
A worked scenario
Usable electron well capacity per pixel = 50000; Current electron charge per pixel = 0; Peak pixel source rate (electrons/s) = 500; Other electron rate per pixel (electrons/s) = 5.
- Time to entered charge limit: 99.009901 s
This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Assumptions and edge cases
Constant pixel rates; blooming, nonlinear response, ADC clipping, and cosmic rays are excluded.
Frequently asked questions
Is full well always the usable limit?
No, enter a lower linearity or ADC-based limit when applicable.
Can I use total star flux?
Use the peak pixel rate, not the full aperture total.
What if no charge arrives?
No finite saturation time can be calculated.
How do I use the Detector saturation exposure time calculator?
Enter Usable electron well capacity per pixel, Current electron charge per pixel, Peak pixel source rate (electrons/s), Other electron rate per pixel (electrons/s). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Detector saturation exposure time?
Usable electron well capacity per pixel = 50000; Current electron charge per pixel = 0; Peak pixel source rate (electrons/s) = 500; Other electron rate per pixel (electrons/s) = 5. Time to entered charge limit: 99.009901 s This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Read our calculation methodology.