How to use this calculator
Estimate ideal free-air equivalent for both strokes of a double-acting cylinder.
- Enter Piston diameter (mm), Rod diameter (mm), Stroke (mm), Full out-and-back cycles/min, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Double acting cylinder free air consumption explained
Use Piston diameter (mm) with Rod diameter (mm) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
How the calculation works
(2*d*d-r*r)*pi/4*s/1e6*n*(p+a)/a
Equal working pressures and equal reference temperatures are assumed; dead volumes and leakage are excluded..
Set up the calculation
d— Piston diameter (mm)- Piston diameter (mm).
r— Rod diameter (mm)- Rod diameter (mm).
s— Stroke (mm)- Stroke (mm).
n— Full out-and-back cycles/min- Full out-and-back cycles/min.
p— Gauge working pressure (bar)- Gauge working pressure (bar).
a— Ambient absolute pressure (bar)- Ambient absolute pressure (bar).
Limits of this model
Equal working pressures and equal reference temperatures are assumed; dead volumes and leakage are excluded.
Check this example
Piston diameter (mm) = 50; Rod diameter (mm) = 20; Stroke (mm) = 200; Full out-and-back cycles/min = 10; Gauge working pressure (bar) = 6; Ambient absolute pressure (bar) = 1.
- Free-air equivalent rate: 50.579642 L/min
Displayed values are rounded only after calculation.
Frequently asked questions
Does one cycle include return?
Yes.
Is pressure gauge or absolute?
Working input is gauge; ambient input is absolute.
Are valve losses included?
No.
How do I use the Double acting cylinder free air consumption calculator?
Enter Piston diameter (mm), Rod diameter (mm), Stroke (mm), Full out-and-back cycles/min, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Double acting cylinder free air consumption?
Piston diameter (mm) = 50; Rod diameter (mm) = 20; Stroke (mm) = 200; Full out-and-back cycles/min = 10; Gauge working pressure (bar) = 6; Ambient absolute pressure (bar) = 1. Free-air equivalent rate: 50.579642 L/min Displayed values are rounded only after calculation.