How to use this calculator
Predict how finite camera integration blurs a dynamic speckle pattern under exponential field decorrelation.
- Enter Camera exposure time (ms), Field correlation decay time (ms), Instrument coherence factor beta. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Dynamic speckle contrast versus camera exposure explained
The exposure integrates intensity fluctuations over a finite interval. For exponentially decaying field correlation, longer exposure averages more of the evolving speckle and lowers contrast; the coherence factor sets the zero-exposure contrast scale.
Inputs, symbols, and units
exposure— Camera exposure time (ms)- Positive rectangular integration time of the camera.
correlation— Field correlation decay time (ms)- Time constant in g1(t)=exp(-abs(t)/tau), not the intensity-correlation time.
beta— Instrument coherence factor beta- Static zero-exposure squared-contrast factor including spatial averaging and polarization.
Formula and method
K²=(2β/T)∫₀ᵀ(1−t/T)|g1(t)|²dt=β[1/x−(1−exp(−2x))/(2x²)], x=T/τc.
Correlation time belongs to the field amplitude. The intensity covariance decays twice as quickly for this exponential field model. A series branch retains the correct frozen-speckle limit for very short exposures.
A worked scenario
Camera exposure time (ms) = 1; Field correlation decay time (ms) = 0.5; Instrument coherence factor beta = 0.8.
- Predicted speckle contrast: 0.549392 RMS intensity / mean intensity
- Predicted squared contrast: 0.301832
- Exposure to field correlation time ratio: 2
A 1 ms exposure, 0.5 ms field correlation time and beta=0.8 produce contrast about 0.55; shorter exposures retain more contrast.
Assumptions and edge cases
Fully dynamic stationary Gaussian speckle and a rectangular exposure. Static scattering, read noise and shot noise require additional terms. No blood-flow velocity or medical interpretation is inferred.
Reading the outputs
Contrast and squared contrast are dimensionless. The final time ratio compares integration with the field dynamics.
Frequently asked questions
Does this return a physical flow speed?
No. Converting correlation time to velocity needs a scattering and geometry model.
Why does exposure reduce contrast?
Different speckle realizations average together within each frame.
What is the very short exposure limit?
K approaches sqrt(beta), rather than necessarily one because spatial and polarization averaging remain.
How do I use the Dynamic speckle contrast versus camera exposure calculator?
Enter Camera exposure time (ms), Field correlation decay time (ms), Instrument coherence factor beta. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Dynamic speckle contrast versus camera exposure?
Camera exposure time (ms) = 1; Field correlation decay time (ms) = 0.5; Instrument coherence factor beta = 0.8. Predicted speckle contrast: 0.549392 RMS intensity / mean intensity Predicted squared contrast: 0.301832 Exposure to field correlation time ratio: 2 A 1 ms exposure, 0.5 ms field correlation time and beta=0.8 produce contrast about 0.55; shorter exposures retain more contrast.
Background or definition reference: Original multi-exposure speckle imaging study and visibility integral.
Read our calculation methodology.