How to use this calculator
Convert a 24-hour PM2.5 concentration to the current U.S. EPA AQI sub-index and category.
- Enter 24-hour PM2.5 concentration (µg/m³). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
This calculator applies the U.S. PM2.5 24-hour concentration breakpoints and the linear AQI equation. The entered concentration is truncated to one decimal place before interpolation. For concentrations above the highest breakpoint, it extends the same final hazardous-category slope used by the EPA method.
Inputs and units
pm25— 24-hour PM2.5 concentration (µg/m³)- Enter the 24-hour average concentration in micrograms per cubic metre.
Formula
Ip = [(IHi − ILo) ÷ (BPHi − BPLo)] × (Cp − BPLo) + ILo; truncate Cp to 0.1 µg/m³ and round Ip to the nearest integer.
Method
Truncate the entered concentration to one decimal place. Select the corresponding PM2.5 24-hour breakpoint interval, interpolate linearly between its AQI endpoints, and round to the nearest integer. Above 325.4 µg/m³, continue the same slope from AQI 301 at 225.5 µg/m³ through AQI 500 at 325.4 µg/m³. The category is Hazardous for AQI 301 and above.
Worked example
A 24-hour PM2.5 average of 35.4 µg/m³ is already at the upper Good-to-Moderate interval endpoint and gives an AQI sub-index of 100, in the Moderate category.
Assumptions and limits
This computes a PM2.5 sub-index from a supplied 24-hour average; it does not retrieve monitor data or produce an official area AQI, which is the highest pollutant sub-index. It is not a medical assessment or a substitute for current AirNow information. Concentrations above the 500 AQI breakpoint remain in the Hazardous category.
Source: U.S. EPA AQI breakpoints — Current PM2.5 24-hour concentration-to-AQI breakpoint table.
Frequently asked questions
Why is the concentration truncated?
The U.S. AQI method truncates 24-hour PM2.5 concentrations to one decimal place before selecting breakpoints.
Is this the full AQI for a city?
No. It calculates only the PM2.5 sub-index; an official area AQI is the highest applicable pollutant sub-index.
How are values above AQI 500 handled?
The hazardous category continues above 500 using the same final linear slope specified in the EPA method.
Should I use this for health decisions?
Use current official AirNow information and public-health guidance. This calculator only performs the stated concentration-to-index arithmetic.
How do I use the EPA PM2.5 AQI Calculator?
Enter 24-hour PM2.5 concentration (µg/m³). Match the units shown beside each field and review the result together with the assumptions below.
Reference: 40 CFR Part 58 Appendix G for current U.S. PM2.5 AQI breakpoints, truncation, interpolation, and hazardous values above 500. See our calculation methodology.