Fanno flow remaining length to choking calculator

Estimate the remaining adiabatic constant-area duct length before a perfect-gas Fanno flow reaches Mach one.

4,000 tools
Fanno flow remaining length to choking calculator — Current Mach number, Heat-capacity ratio, Constant duct hydraulic diameter (m) and calculation method
Fanno flow remaining length to choking calculator: inputs and calculation method.

How to use this calculator

Estimate the remaining adiabatic constant-area duct length before a perfect-gas Fanno flow reaches Mach one.

  1. Enter Current Mach number, Heat-capacity ratio, Constant duct hydraulic diameter (m), Darcy friction factor. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Fanno flow remaining length to choking explained

This Fanno estimate relates subsonic Mach number and wall friction to the remaining constant-area duct length before the flow reaches sonic conditions.

Remaining duct length to sonic state26.4963m
Remaining duct length to sonic state: 26.49626553 m in the worked scenario.

Inputs, symbols, and units

m — Current Mach number
Current Mach number.
g — Heat-capacity ratio
Heat-capacity ratio.
d — Constant duct hydraulic diameter (m)
Constant duct hydraulic diameter (m).
f — Darcy friction factor
Darcy friction factor.

Formula and method

fDarcy·L*/D=(1−M²)/(γM²)+(γ+1)/(2γ)ln[(γ+1)M²/(2+(γ−1)M²)]

Evaluate the dimensionless sonic-length function at the current Mach and gamma. In the Darcy convention its value is fL*/D, so multiply by diameter and divide by Darcy friction factor. The same expression approaches zero at Mach one from either branch.

A worked scenario

Current Mach number = 0.3; Heat-capacity ratio = 1.4; Constant duct hydraulic diameter (m) = 0.1; Darcy friction factor = 0.02.

  • Remaining duct length to sonic state: 26.49626553 m
  • Darcy fL/D sonic parameter: 5.29925311

This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.

Assumptions and edge cases

Constant Darcy factor, diameter, and gamma. The displayed friction factor is Darcy, four times the Fanning convention; heat transfer is excluded.

Frequently asked questions

Does this use Fanning friction factor?

No, enter the Darcy factor.

Can supersonic inlet flow be entered?

Yes, friction drives it toward Mach one under the same ideal model.

What if M=1?

Remaining modeled length is zero.

How do I use the Fanno flow remaining length to choking calculator?

Enter Current Mach number, Heat-capacity ratio, Constant duct hydraulic diameter (m), Darcy friction factor. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Fanno flow remaining length to choking?

Current Mach number = 0.3; Heat-capacity ratio = 1.4; Constant duct hydraulic diameter (m) = 0.1; Darcy friction factor = 0.02. Remaining duct length to sonic state: 26.49626553 m Darcy fL/D sonic parameter: 5.29925311 This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.