Fresh Concrete Pressure-Meter Air Correction Calculator

Correct a fresh-concrete pressure-meter air reading by subtracting its aggregate correction factor.

4,000 tools
Fresh Concrete Pressure-Meter Air Correction Calculator — Pressure-meter gauge reading (%), Aggregate correction factor (%) and calculation method
Fresh Concrete Pressure-Meter Air Correction Calculator: inputs and calculation method.

How to use this calculator

Correct a fresh-concrete pressure-meter air reading by subtracting its aggregate correction factor.

  1. Enter Pressure-meter gauge reading (%), Aggregate correction factor (%). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Construction calculation

How this calculation works

Enter the air-content reading shown by the pressure meter and the aggregate correction factor established for aggregate used in the tested concrete. Enter both values in percentage points.

Inputs and units

gaugeReading — Pressure-meter gauge reading (%)
Air-content reading before aggregate correction.
aggregateCorrection — Aggregate correction factor (%)
Factor established for the aggregate under the applicable test procedure.

Formula

Displayed formula

Corrected air content (%) = pressure-meter gauge reading (%) - aggregate correction factor (%).

Method

Subtract the aggregate correction factor from the gauge reading. The factor must be determined for the aggregate and test setup under the governing method.

Worked example

For a pressure-meter reading of 6.2% and an aggregate correction factor of 0.4 percentage points, corrected air content is 5.8%.

Assumptions and limits

Use the pressure-method correction only for applicable fresh concrete made with relatively dense aggregates for which a correction factor can be determined. ASTM C231/C231M excludes lightweight and high-porosity aggregate applications. This calculator does not perform the pressure test.

Frequently asked questions

Why is the aggregate correction subtracted?

The pressure-meter reading includes aggregate pressure response; the applicable factor is subtracted to obtain corrected air content.

Can I use the pressure method for lightweight aggregate?

ASTM C231/C231M excludes lightweight and high-porosity aggregates; consult the appropriate volumetric method.

Where does the correction factor come from?

Determine it using the applicable standard procedure and the aggregate being tested.

How do I use the Fresh Concrete Pressure-Meter Air Correction Calculator?

Enter Pressure-meter gauge reading (%), Aggregate correction factor (%). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Fresh Concrete Pressure-Meter Air Correction?

For a pressure-meter reading of 6.2% and an aggregate correction factor of 0.4 percentage points, corrected air content is 5.8%.