Gapped magnetic-core inductance and saturation calculator

Estimate how a deliberate air gap trades inductance for usable DC current in a magnetic-core inductor.

4,000 tools
Gapped magnetic-core inductance and saturation calculator — Winding turns, Core effective area (m2), Core path length (m) and calculation method
Gapped magnetic-core inductance and saturation calculator: inputs and calculation method.

How to use this calculator

Estimate how a deliberate air gap trades inductance for usable DC current in a magnetic-core inductor.

  1. Enter Winding turns, Core effective area (m2), Core path length (m), Relative core permeability, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Gapped magnetic-core inductance and saturation explained

The air gap often dominates magnetic reluctance, so changing gap length can strongly affect both calculated inductance and current at the stated flux limit.

Inputs, symbols, and units

N — Winding turns
Actual complete turns around the core. Enter a whole number.
A — Core effective area (m2)
Uniform core and gap flux cross-section.
lc — Core path length (m)
Mean magnetic path inside the core material.
mur — Relative core permeability
Assumed constant differential permeability.
g — Total physical gap (m)
Sum of series air-gap lengths; zero is allowed.
I — Peak winding current (A)
Peak current producing peak modeled flux.
Bmax — Flux-density limit (T)
Chosen material operating limit, not automatically a saturation rating.

Formula and method

L=μ_0N²A/(l_C/μ_r+g); B=μ_0NI/(l_C/μ_r+g); I_LIMIT=B_LIMIT(l_C/μ_r+g)/(μ_0N).

Core and air gap are series reluctances with the same cross-section. The entered limit is a design flux density; the linear model does not simulate actual saturation.

A worked scenario

Winding turns = 50; Core effective area (m2) = 0.0001; Core path length (m) = 0.08; Relative core permeability = 2000; Total physical gap (m) = 0.001; Peak winding current (A) = 3; Flux-density limit (T) = 0.3.

  • Inductance: 0.000302 H
  • Peak core flux density: 0.181246 T
  • Current at chosen flux limit: 4.965634 A

Fifty turns on a 100 mm² core with an 80 mm path and 1 mm total gap are evaluated at 3 A before comparison with a 0.3 T design ceiling.

Assumptions and edge cases

No fringing, gap-edge loss, winding leakage, hysteresis or nonlinear B-H curve. Large gaps and distributed-gap powders need better geometry/material models.

Reading the outputs

Inductance is henries, flux is tesla and the current limit is the current reaching the entered flux ceiling in this model.

Frequently asked questions

Does doubling the gap double usable current?

Approximately when gap reluctance dominates, but inductance falls at the same time.

Is Bmax a universal ferrite constant?

No; choose a value from the material and frequency/temperature design requirements.

Why is physical gap not always equal to effective gap?

Fringing increases effective gap area and modifies reluctance.

How do I use the Gapped magnetic-core inductance and saturation calculator?

Enter Winding turns, Core effective area (m2), Core path length (m), Relative core permeability, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Gapped magnetic-core inductance and saturation?

Winding turns = 50; Core effective area (m2) = 0.0001; Core path length (m) = 0.08; Relative core permeability = 2000; Total physical gap (m) = 0.001; Peak winding current (A) = 3; Flux-density limit (T) = 0.3. Inductance: 0.000302 H Peak core flux density: 0.181246 T Current at chosen flux limit: 4.965634 A Fifty turns on a 100 mm² core with an 80 mm path and 1 mm total gap are evaluated at 3 A before comparison with a 0.3 T design ceiling.