Magnetic flux walk from asymmetric switching calculator

Check transformer or coupled-inductor flux balance when positive and reset volt-seconds are not equal.

4,000 tools
Magnetic flux walk from asymmetric switching calculator — Winding turns, Core effective area (m2), Positive pulse voltage (V) and calculation method
Magnetic flux walk from asymmetric switching calculator: inputs and calculation method.

How to use this calculator

Check transformer or coupled-inductor flux balance when positive and reset volt-seconds are not equal.

  1. Enter Winding turns, Core effective area (m2), Positive pulse voltage (V), Positive pulse duration (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Magnetic flux walk from asymmetric switching explained

Check transformer or coupled-inductor flux balance when positive and reset volt-seconds are not equal.

Net flux walk after cycles0.5T
Net flux walk after cycles: 0.5 T in the worked scenario.

How the calculation works

ΔB_+=V_+t_+/(NA); ΔB_CYCLE=(V_+t_+−V_−t_−)/(NA); B_WALK=n ΔB_CYCLE.

Use winding voltage rather than bus voltage when switch and reflected-output drops matter. The sum of winding volt-seconds must approach zero for bounded periodic flux.

Set up the calculation

N — Winding turns
Turns linking the core flux. Enter a whole number.
A — Core effective area (m2)
Flux cross-section through the winding.
Vp — Positive pulse voltage (V)
Positive voltage directly across the winding.
tp — Positive pulse duration (s)
Duration of the positive winding voltage.
Vn — Negative reset voltage magnitude (V)
Magnitude of negative winding voltage.
tn — Negative reset duration (s)
Duration of reset voltage.
cycles — Repeated cycles
Cycles over which net flux accumulation is extrapolated. Enter a whole number.

Limits of this model

Fixed voltages and durations, linear extrapolation only until feedback, current limiting or core saturation changes the waveform.

Check this example

Winding turns = 30; Core effective area (m2) = 0.00008; Positive pulse voltage (V) = 24; Positive pulse duration (s) = 0.000005; Negative reset voltage magnitude (V) = 12; Negative reset duration (s) = 0.000009; Repeated cycles = 100.

  • Net flux walk after cycles: 0.5 T
  • Positive pulse flux rise: 0.05 T
  • Net flux change per cycle: 0.005 T/cycle

A 24 V, 5 microsecond forward pulse is reset by only 12 V for 9 microseconds; the small imbalance accumulates across 100 cycles.

Reading the outputs

Flux walk is an extrapolated change from the initial state, not an absolute flux density. Add the initial bias before judging saturation.

Frequently asked questions

Can balanced volt-seconds still saturate a core?

Yes; excessive within-cycle swing or an initial DC offset can reach the material limit.

Why enter reset voltage as positive?

Its opposing polarity is already included by subtraction in the formula.

Does the extrapolation stay valid after saturation?

No; the circuit current and voltage waveform usually change dramatically.

How do I use the Magnetic flux walk from asymmetric switching calculator?

Enter Winding turns, Core effective area (m2), Positive pulse voltage (V), Positive pulse duration (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Magnetic flux walk from asymmetric switching?

Winding turns = 30; Core effective area (m2) = 0.00008; Positive pulse voltage (V) = 24; Positive pulse duration (s) = 0.000005; Negative reset voltage magnitude (V) = 12; Negative reset duration (s) = 0.000009; Repeated cycles = 100. Net flux walk after cycles: 0.5 T Positive pulse flux rise: 0.05 T Net flux change per cycle: 0.005 T/cycle A 24 V, 5 microsecond forward pulse is reset by only 12 V for 9 microseconds; the small imbalance accumulates across 100 cycles.