How to use this calculator
Estimate the minimum and maximum I2C pull-up resistance allowed by sink-current and rise-time limits.
- Enter Bus supply voltage (V), Maximum low-level voltage VOL (V), Allowed sink current (mA), Total bus capacitance (pF), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
An I2C pull-up must be strong enough that the lowest-voltage device can sink the resulting current, yet weak enough to charge the bus capacitance within the permitted rise time. Comparing these bounds gives a feasible resistor interval for the entered bus assumptions.
Inputs and units
vdd— Bus supply voltage (V)- I2C pull-up rail voltage in volts.
volMax— Maximum low-level voltage VOL (V)- Maximum device output-low voltage at the stated sink current.
sinkCurrentMa— Allowed sink current (mA)- Lowest applicable device sink-current limit in milliamps.
busCapacitancePf— Total bus capacitance (pF)- Estimated total SDA or SCL capacitance in picofarads.
riseTimeNs— Maximum rise time (ns)- Allowed 30%-to-70% rise time in nanoseconds for the selected I2C mode.
Formula
Rmin = (VDD − VOLmax) ÷ IOL; Rmax = tr ÷ (0.8473 × Cb); a feasible interval exists when Rmin ≤ Rmax.
Method
Enter bus supply, the maximum low-level voltage at the sink-current limit, the weakest participating device's allowed sink current, total bus capacitance, and the maximum rise time. The calculator converts pF and ns consistently and reports both resistance bounds and whether they overlap.
Worked example
With a 3.3 V bus, VOL = 0.4 V, 3 mA sink-current limit, 100 pF bus capacitance, and 300 ns rise-time limit, Rmin is 966.7 Ω and Rmax is 3,540.7 Ω, so a feasible resistor interval exists.
Assumptions and limits
This is a first-order I2C pull-up check based on the entered lumped bus capacitance and device sink-current limit. Check every device's voltage limits, parallel pull-ups, leakage, wiring, bus mode rise-time specification, and resistor tolerance in the actual circuit; a feasible calculated interval does not validate a complete design.
Frequently asked questions
Why are there two resistor limits?
The minimum limits low-state sink current, while the maximum allows the bus capacitance to rise quickly enough.
What does no feasible interval mean?
The entered current and rise-time constraints do not overlap; lower capacitance, a different bus mode, or suitable buffering may be needed.
Can I use the same value for SDA and SCL?
Often the same nominal value is used, but check each line's capacitance, device limits, and any parallel pull-ups separately.
How do I use the I2C Pull-Up Resistor Range Calculator?
Enter Bus supply voltage (V), Maximum low-level voltage VOL (V), Allowed sink current (mA), Total bus capacitance (pF), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of I2C Pull-Up Resistor Range?
With a 3.3 V bus, VOL = 0.4 V, 3 mA sink-current limit, 100 pF bus capacitance, and 300 ns rise-time limit, Rmin is 966.7 Ω and Rmax is 3,540.7 Ω, so a feasible resistor interval exists.
Reference: NXP I2C-bus specification covering pull-up resistance bounds, rise time, capacitance, and sink current. See our calculation methodology.