How to use this calculator
Solve where an NMOS transistor characteristic intersects its drain-resistor load line, including cutoff, saturation and triode operation.
- Enter Drain supply (V), Gate-source voltage (V), Threshold voltage (V), Process transconductance K (A/V2), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Resistor-loaded MOSFET operating point explained
The ideal long-channel square-law model tests a saturation candidate against the drain load line, then solves the triode-region intersection if needed. Its K convention includes the one-half factor in saturation current; real-device channel-length modulation, temperature and datasheet behavior are omitted.
Inputs, symbols, and units
Vdd— Drain supply (V)- Positive supply at the top of drain resistor.
Vg— Gate-source voltage (V)- Gate bias relative to grounded source.
Vt— Threshold voltage (V)- Long-channel threshold in the square-law model.
K— Process transconductance K (A/V2)- K equals mobility times oxide capacitance per area times W/L.
Rd— Drain resistance (ohm)- Positive drain load resistance.
Formula and method
I_D=K(V_GS−V_T)^2/2 in saturation; I_D=K[(V_GS−V_T)V_DS−V_DS²/2] in triode; I_D=(V_DD−V_DS)/R_D.
The saturation candidate is checked against VDS≥VGS−VT. Otherwise a bracketed load-line root determines the triode point.
A worked scenario
Drain supply (V) = 5; Gate-source voltage (V) = 2.5; Threshold voltage (V) = 1.5; Process transconductance K (A/V2) = 0.01; Drain resistance (ohm) = 470.
- Drain current: 0.005 A
- Drain-source voltage: 2.65 V
- Triode-region flag: 0 0 saturation/cutoff; 1 triode
A 5 V supply, 470 ohm load and 2.5 V gate bias produce a saturation operating point for K=0.01 A/V² and VT=1.5 V.
Assumptions and edge cases
Long-channel enhancement NMOS with grounded source; ignores channel-length modulation, body effect and subthreshold leakage.
Reading the outputs
The region flag distinguishes the linear-resistance region from saturation; current and voltage remain the primary physical outputs.
Frequently asked questions
Does saturation mean a fully on switch?
No. MOSFET saturation is the current-source region; a low-resistance switch usually operates in triode.
Can the gate be below threshold?
Yes; this ideal model returns zero drain current.
Can power MOSFET datasheet RDS(on) replace K?
No. The square-law parameter and specified on-resistance describe different models.
How do I use the Resistor-loaded MOSFET operating point calculator?
Enter Drain supply (V), Gate-source voltage (V), Threshold voltage (V), Process transconductance K (A/V2), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Resistor-loaded MOSFET operating point?
Drain supply (V) = 5; Gate-source voltage (V) = 2.5; Threshold voltage (V) = 1.5; Process transconductance K (A/V2) = 0.01; Drain resistance (ohm) = 470. Drain current: 0.005 A Drain-source voltage: 2.65 V Triode-region flag: 0 0 saturation/cutoff; 1 triode A 5 V supply, 470 ohm load and 2.5 V gate bias produce a saturation operating point for K=0.01 A/V² and VT=1.5 V.
Background or definition reference: Analog Devices Chapter 8: MOSFET large-signal models.
Read our calculation methodology.