A resistor-loaded NMOS operating point is where the transistor’s current curve meets the drain-resistor load line. With VDD = 12 V, VGS = 4 V, VT = 2 V, K = 0.010 A/V², and RD = 1 kΩ, the calculator finds about 11.318 mA and VDS = 0.682 V in its triode model. A different bias can move the intersection into saturation; the region matters as much as the current value.

Open calculator
A MOSFET output curve meets a resistor load line at a marked operating point.

Share this article

A descending resistor load line intersects the rising family of MOSFET output curves at a marked operating point.
The bias point satisfies both the transistor current relation and the drain-resistor equation.

The resistor and transistor must agree

The drain resistor sets a straight-line relationship between drain current and drain-to-source voltage: ID = (VDD − VDS)/RD for a grounded source and a supply at the top of the resistor. The transistor contributes its own current relation, which changes with gate overdrive and VDS. The operating point is the pair of values that satisfies both relationships at once.

Changing RD or VGS moves the intersection: the load line changes with resistance, while the device curve changes with overdrive. The calculator’s region flag identifies the equation used; it is not a small-signal gain or a full circuit simulation.

Understand the square-law regions

The model uses overdrive VOV = max(0, VGS − VT). At or below threshold it reports cutoff: ID = 0 and VDS = VDD. In saturation it uses ID = K VOV²/2. In triode it uses ID = K(VOVVDS − VDS²/2). The boundary is VDS = VOV. These are ideal long-channel square-law expressions, not a detailed modern MOSFET compact model.

K is in A/V² and follows the calculator’s convention: saturation uses ID = K·VOV²/2; triode uses ID = K(VOV·VDS − VDS²/2). The tool intersects that curve with the resistor line and reports current, VDS, and a triode flag.

Read the first intersection

For VDD = 12 V, VGS = 4 V, VT = 2 V, K = 0.010 A/V², and RD = 1,000 Ω, VOV = 2 V. The 20 mA saturation estimate would require a 20 V resistor drop, exceeding the supply, so the final point must lie in triode.

Solving the triode and load-line equations gives VDS ≈ 0.682255 V and ID ≈ 11.317745 mA. Substitution gives (12 − 0.682255)/1,000 ≈ 11.317745 mA, confirming the displayed point within rounding.

Compare a saturation operating point

For VDD = 12 V, VGS = 3 V, VT = 1.5 V, K = 0.010 A/V², and RD = 330 Ω, VOV = 1.5 V. The saturation current is 11.25 mA; the 3.7125 V resistor drop leaves VDS = 8.2875 V.

Because VDS exceeds VOV, this point remains in saturation under the square-law model. The contrast with the first case shows how the load can determine the operating region even when both use the same device equation.

Worked examples

A resistor forces the device into triode

Inputs: VDD = 12 V, VGS = 4 V, VT = 2 V, K = 0.010 A/V², RD = 1,000 Ω.

Calculation: VOV = 2 V; ID,sat = 0.010 × 2²/2 = 20 mA, which would imply negative VDS. Solving the triode/load-line intersection gives VDS = 0.682255 V and ID = (12 − 0.682255)/1,000 = 11.317745 mA.

VDS is below VOV, so the model uses the triode branch and reports a triode flag of 1.

A lower overdrive stays in saturation

Inputs: VDD = 12 V, VGS = 3 V, VT = 1.5 V, K = 0.010 A/V², RD = 330 Ω.

Calculation: VOV = 1.5 V; ID = 0.010 × 1.5²/2 = 11.25 mA; VDS = 12 − (0.01125 × 330) = 8.2875 V.

Because VDS > VOV, the saturation branch is consistent; the reported triode flag is 0.

Cutoff, triode, and saturation regions are separated by threshold and overdrive boundaries.
The model selects a current equation according to gate overdrive and drain voltage.

Use the result for bias planning

A common-source amplifier is often biased in saturation to provide voltage gain, with enough drain-voltage headroom for the intended signal swing. A switch may instead be designed for a low VDS in the linear or triode region, but its power, temperature, and on-resistance then need a more appropriate device model. The word “linear region” is also used differently across power-MOSFET contexts, so state whether you mean the square-law triode region or a datasheet safe-operating region.

Compare the static point with required signal swing and supply headroom. A point near a region boundary can move as K, threshold, temperature, or supply varies; use a device model for final design.

Know the model limits and verify

The model assumes a grounded source, enhancement NMOS, positive drain supply and resistor, and a long-channel square-law device. It omits channel-length modulation, body effect, temperature, parasitic resistance, and capacitance.

On a bench, measure VGS and VDS after settling, then compute ID from the resistor drop. A mismatch can reveal wiring, parameter, or modeling assumptions that need attention.