How to use this calculator
Estimate the irrigation leaching fraction from water salinity and a crop soil-salinity threshold.
- Enter Irrigation water ECw (dS/m), Crop soil salinity threshold ECe (dS/m), Net crop water depth (mm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Irrigation water carries dissolved salts into the root zone. The FAO screening equation estimates the fraction of applied irrigation that must drain below the root zone to limit salinity for a selected crop; an optional net water depth converts that fraction into a simple gross-depth estimate.
Inputs and units
ecw— Irrigation water ECw (dS/m)- Use electrical conductivity of the irrigation water in dS/m.
ece— Crop soil salinity threshold ECe (dS/m)- Use the crop tolerance value expressed as saturated-paste extract conductivity in the same units.
netDepthMm— Net crop water depth (mm)- Enter the net depth needed by the crop; this is used only for the gross-depth estimate.
Formula
LR = ECw ÷ (5 × ECe − ECw); gross irrigation depth = net crop water depth ÷ (1 − LR), where ECw and ECe use the same electrical-conductivity units.
Method
Enter irrigation-water electrical conductivity, the crop's tolerated soil salinity as ECe, and optional net irrigation depth. The FAO relationship estimates LR; gross depth assumes the leached share is LR and the remainder supplies the stated net depth.
Worked example
With ECw = 0.8 dS/m, ECe = 4 dS/m, and 500 mm net depth, LR = 0.8/(20−0.8) ≈ 4.17%; gross depth is 500/(1−0.0417) ≈ 521.74 mm.
Assumptions and limits
This is a screening relationship for specified salinity and irrigation assumptions, not a drainage or irrigation-system design. It omits rainfall, groundwater contribution, application uniformity, salt composition, and site-specific root-zone processes; consult local agronomic guidance.
Frequently asked questions
Do ECw and ECe need the same units?
Yes. Both conductivities must use the same unit, commonly dS/m, so their ratio is dimensionless.
Does leaching requirement equal the extra water percentage over crop need?
LR is the fraction of applied water that drains below the root zone. Gross depth is calculated by dividing net depth by 1−LR, so the added fraction of net depth is not numerically identical to LR.
Can the result replace an irrigation design?
No. It is a simplified salinity estimate and omits field drainage, application efficiency, rainfall, groundwater, and crop-specific management details.
How do I use the Irrigation leaching requirement calculator?
Enter Irrigation water ECw (dS/m), Crop soil salinity threshold ECe (dS/m), Net crop water depth (mm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Irrigation leaching requirement?
With ECw = 0.8 dS/m, ECe = 4 dS/m, and 500 mm net depth, LR = 0.8/(20−0.8) ≈ 4.17%; gross depth is 500/(1−0.0417) ≈ 521.74 mm.
Reference: FAO meteorological calculation guidance. See our calculation methodology.