How to use this calculator
Compare a measured gas state against PV=nRT using the dimensionless compressibility factor.
- Enter Absolute pressure (bar), Measured volume (L), Amount (mol), Temperature (K). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Measured gas compressibility factor explained
This measured P–V state is compared with the ideal-gas reference for the same amount and temperature.
A numerical walkthrough
Absolute pressure (bar) = 10; Measured volume (L) = 2.4; Amount (mol) = 1; Temperature (K) = 300.
- Measured gas compressibility factor: 0.962179
For 1 mol at 300 K in 2.4 L, the ideal-gas reference pressure is about 10.393 bar. A measured 10 bar gives Z ≈ 0.962; this compares one measured state with PV = nRT and does not predict Z from gas identity.
The model behind the numbers
Z = pV/(nRT), using R = 0.083144626 L·bar·mol⁻¹·K⁻¹ when p is bar, V is L, n is mol, and T is K.
Use absolute pressure and measurements from the same sample at the same temperature. Z compares that measured state with the ideal-gas relation; it does not predict non-ideality from gas identity..
What to enter
p— Absolute pressure (bar)- Measured absolute pressure in bar; gauge pressure must first be converted to absolute pressure.
vol— Measured volume (L)- Volume of the same gas sample at the entered pressure and temperature.
n— Amount (mol)- Amount of substance in that measured sample, in moles.
t— Temperature (K)- Absolute sample temperature in kelvins for the same measured state.
Interpreting the result
All state measurements must refer to the same sample and temperature; this does not predict Z from gas identity.
Verified reference: OpenStax Chemistry, Non-Ideal Gas Behavior and Compressibility Factor.
Frequently asked questions
What does Z=1 mean?
The measured state agrees with ideal-gas PV=nRT.
May gauge pressure be used?
Convert it to absolute pressure.
Is Z a viscosity correction?
No.
How do I use the Measured gas compressibility factor calculator?
Enter Absolute pressure (bar), Measured volume (L), Amount (mol), Temperature (K). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Measured gas compressibility factor?
Absolute pressure (bar) = 10; Measured volume (L) = 2.4; Amount (mol) = 1; Temperature (K) = 300. Measured gas compressibility factor: 0.962179 For 1 mol at 300 K in 2.4 L, the ideal-gas reference pressure is about 10.393 bar. A measured 10 bar gives Z ≈ 0.962; this compares one measured state with PV = nRT and does not predict Z from gas identity.
Read our calculation methodology.