Place a real zero-pole pair to supply a selected maximum positive phase contribution near a loop crossover.

4,000 tools
Phase lead compensator design calculator — Desired maximum phase lead (deg), Frequency of maximum lead (rad/s), DC gain and calculation method
Phase lead compensator design calculator: inputs and calculation method.

How to use this calculator

Place a real zero-pole pair to supply a selected maximum positive phase contribution near a loop crossover.

  1. Enter Desired maximum phase lead (deg), Frequency of maximum lead (rad/s), DC gain. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Phase lead compensator design explained

Use Desired maximum phase lead (deg) with Frequency of maximum lead (rad/s) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.

Zero angular frequency2.0823rad/s
Zero angular frequency: 2.082268 rad/s in the worked scenario.

A numerical walkthrough

Desired maximum phase lead (deg) = 35; Frequency of maximum lead (rad/s) = 4; DC gain = 1.

  • Zero angular frequency: 2.082268 rad/s
  • Pole angular frequency: 7.683929 rad/s
  • Magnitude at peak lead: 1.920982 ratio

Request 35 degrees of maximum lead centered at four radians per second while retaining unit DC gain.

The model behind the numbers

C(s)=K(1+Ts)/(1+αTs); α=(1−sinφ)/(1+sinφ), T=1/(ωm√α).

The pole lies above the zero because alpha is below one. The requested lead also raises magnitude at its center frequency.

What to enter

phi — Desired maximum phase lead (deg)
Peak positive phase contribution, strictly between zero and ninety degrees.
w — Frequency of maximum lead (rad/s)
Place the peak lead at this positive angular frequency.
K — DC gain
Positive gain of the compensator at zero frequency.

Interpreting the result

Does not solve the full loop crossover problem. Nearly ninety-degree requests require extreme pole-zero separation.

Reading the outputs

Zero and pole are positive break frequencies; the third result is the magnitude multiplier at the lead peak.

Frequently asked questions

Is the zero in the right half-plane?

No. A positive break frequency means a zero at s=−ωz.

Will this guarantee the desired phase margin?

No; plant phase and the shifted crossover must also be checked.

Why does magnitude increase?

The zero begins boosting gain before the higher-frequency pole limits it.

How do I use the Phase lead compensator design calculator?

Enter Desired maximum phase lead (deg), Frequency of maximum lead (rad/s), DC gain. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Phase lead compensator design?

Desired maximum phase lead (deg) = 35; Frequency of maximum lead (rad/s) = 4; DC gain = 1. Zero angular frequency: 2.082268 rad/s Pole angular frequency: 7.683929 rad/s Magnitude at peak lead: 1.920982 ratio Request 35 degrees of maximum lead centered at four radians per second while retaining unit DC gain.