How to use this calculator
Estimate the downward drag action accumulated above a separately identified pile neutral plane in settling ground.
- Enter Settling layer depth to neutral plane (m), Pile perimeter (m), Effective stress at top of drag zone (kPa), Effective stress gradient (kPa/m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Pile dragload above an entered neutral plane explained
Enter the assumed neutral-plane depth, pile perimeter, effective-stress profile, β factor, and sustained head load to estimate downdrag and axial force at the neutral plane.
A numerical walkthrough
Settling layer depth to neutral plane (m) = 8; Pile perimeter (m) = 1.5; Effective stress at top of drag zone (kPa) = 10; Effective stress gradient (kPa/m) = 9; Negative shaft beta factor = 0.25; Pile-head permanent load (kN) = 600.
- Maximum axial force at neutral plane: 738 kN
- Integrated dragload: 138 kN
- Drag shear at neutral plane: 20.5 kPa
A 1.5 m perimeter pile has an 8 m drag zone, effective stress starting at 10 kPa and rising 9 kPa/m, β=0.25 and a 600 kN head load.
The model behind the numbers
D=perimeter·β∫0^L(σ′top+γ′z)dz=perimeter·β(σ′topL+γ′L²/2); Nneutral=Phead+D.
The neutral-plane depth is an input because it depends on pile-soil movement compatibility. Dragload is added to structural axial action, rather than subtracted blindly from geotechnical resistance.
What to enter
L— Settling layer depth to neutral plane (m)- Embedded length over which downward shaft shear is mobilized.
per— Pile perimeter (m)- Shaft contact perimeter.
s0— Effective stress at top of drag zone (kPa)- Effective overburden at the beginning of the settling zone.
gp— Effective stress gradient (kPa/m)- Linear increase in effective vertical stress with depth.
beta— Negative shaft beta factor- Specified factor relating drag shear to effective vertical stress.
P— Pile-head permanent load (kN)- Sustained downward action added to dragload for the maximum axial force estimate.
Interpreting the result
This estimate assumes fully mobilized negative shaft resistance, a linear effective-stress profile, and an entered neutral-plane depth. It does not solve pile-soil movement compatibility or partial mobilization; determine design actions under the governing geotechnical framework.
Reading the outputs
Maximum neutral-plane axial force and dragload are kN; the local bottom drag shear is kPa.
Frequently asked questions
Can the neutral plane be assumed at the layer base?
Only if a compatibility assessment supports it; the calculator does not locate it.
Is dragload a transient live load?
It is a movement-induced action associated with sustained ground settlement, with treatment depending on the design framework.
What does zero drag-zone length return?
Zero dragload and an axial force equal to the entered pile-head load.
How do I use the Pile dragload above an entered neutral plane calculator?
Enter Settling layer depth to neutral plane (m), Pile perimeter (m), Effective stress at top of drag zone (kPa), Effective stress gradient (kPa/m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Pile dragload above an entered neutral plane?
Settling layer depth to neutral plane (m) = 8; Pile perimeter (m) = 1.5; Effective stress at top of drag zone (kPa) = 10; Effective stress gradient (kPa/m) = 9; Negative shaft beta factor = 0.25; Pile-head permanent load (kN) = 600. Maximum axial force at neutral plane: 738 kN Integrated dragload: 138 kN Drag shear at neutral plane: 20.5 kPa A 1.5 m perimeter pile has an 8 m drag zone, effective stress starting at 10 kPa and rising 9 kPa/m, β=0.25 and a 600 kN head load.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume II.
Reference access note: The FHWA manual provides geotechnical background; this simplified entered-β model does not locate the neutral plane. Confirm load cases and design factors under the governing project standard.
Read our calculation methodology.