How to use this calculator
Estimate a plate-load subgrade reaction modulus from applied load, circular plate size, and recoverable deflection.
- Enter Net applied plate load (kN), Circular plate diameter (mm), Recoverable elastic rebound (mm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Reduce one circular plate-load observation to average contact pressure and a secant subgrade reaction coefficient. Enter the net load at the observation and only the recoverable elastic rebound measured for that load level.
Inputs and units
appliedLoadKn— Net applied plate load (kN)- Use the net applied load corresponding to the entered rebound, after any load-cell or apparatus corrections.
plateDiameterMm— Circular plate diameter (mm)- Diameter of the loaded round plate; the area is calculated as πD²/4.
recoverableDeflectionMm— Recoverable elastic rebound (mm)- Elastic/recoverable vertical movement associated with the load level. Exclude permanent deformation.
Formula
A = πD²/4; q = P/A; kₛ = q/δᵉ. With q in kPa and δᵉ in mm, kₛ is in kPa/mm, numerically equal to MN/m³.
Method
Compute the loaded circular area from diameter, divide the net plate load by area for average contact pressure, then divide pressure by recoverable elastic rebound. The result is the secant coefficient for the stated test point.
Worked example
A net load of 10 kN on a 300 mm diameter plate gives 141.47 kPa average pressure. With 1.25 mm recoverable elastic rebound, the secant subgrade reaction modulus is 113.18 kPa/mm, or 113.18 MN/m³.
Assumptions and limits
Subgrade reaction is a Winkler-model coefficient, not an intrinsic soil constant. It varies with loaded area and shape, pressure level, position, and support conditions; plate size effects and plate bending are not corrected here. Use only recoverable elastic rebound, not permanent settlement. Do not use this screening reduction as a foundation design value without project-specific interpretation and scale corrections.
Frequently asked questions
Why use recoverable rebound?
The cited FHWA rigid-pavement procedure defines the measured k value from elastic, recoverable plate movement and excludes permanent deformation.
Is this k value a soil constant?
No. It depends on loaded area and shape, pressure level, and position, and it may need adjustment for the actual foundation geometry.
Does the calculator determine a design value?
No. It reduces a stated plate-test point only; plate bending, scale effects, test protocol, and project conditions need engineering review.
How do I use the Plate Load Subgrade Reaction Modulus Calculator?
Enter Net applied plate load (kN), Circular plate diameter (mm), Recoverable elastic rebound (mm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Plate Load Subgrade Reaction Modulus?
A net load of 10 kN on a 300 mm diameter plate gives 141.47 kPa average pressure. With 1.25 mm recoverable elastic rebound, the secant subgrade reaction modulus is 113.18 kPa/mm, or 113.18 MN/m³.
Reference: FHWA GEC 5 coefficient of subgrade reaction definition and plate-size caveats. See our calculation methodology.