CalcWorldHub
Free online calculator · no signup

Ponded Green Ampt infiltration progress calculator

Solve ponded infiltration progress for a stated soil and elapsed time.

4,000 tools
Ponded Green Ampt infiltration progress calculator — Saturated hydraulic conductivity (mm/hour), Wetting-front suction magnitude (mm), Moisture deficit and calculation method
Ponded Green Ampt infiltration progress calculator: inputs and calculation method.

How to use this calculator

Estimate cumulative Green–Ampt infiltration and current capacity during continuous ponding.

  1. Enter Saturated hydraulic conductivity (mm/hour), Wetting-front suction magnitude (mm), Moisture deficit, Ponded infiltration duration (hours). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.

Estimate cumulative infiltration during continuous ponding

The Green–Ampt model treats infiltration as a sharp wetting front advancing through a uniform soil profile. This calculator solves the implicit cumulative-infiltration relation and reports the current infiltration capacity.

Inputs and units

Formula and method

Let A = ψΔθ. For ponded infiltration, solve F − A ln(1+F/A) = Kt for cumulative infiltration F. Capacity at that time is f = K(1 + A/F). When A = 0, F = Kt.

Worked example

With K = 10 mm/h, ψ = 120 mm, Δθ = 0.25, and t = 2 h, A = 30 mm. Solving the relation gives F ≈ 49.0766 mm and capacity f = 10(1+30/49.0766) ≈ 16.1129 mm/h.

Interpreting the result

The result models about 49.1 mm infiltrated since ponding began. Capacity is the instantaneous rate under the modeled soil state, not necessarily the rainfall rate or actual infiltration rate when water supply is limited.

Assumptions and limits

Assumes a homogeneous profile, initially uniform moisture, a sharp wetting front, and ponding from time zero. It excludes rainfall-limited preponding, layered soils, lateral flow, crusting, and changing surface storage.

Green-Ampt wetting front in ponded soilWater ponds at the soil surface while a sharp wetting front moves downward. The front depth corresponds to cumulative infiltration F.ponded waterwetting zonefront, Funiform profile and continuous ponding assumed
The Green–Ampt model idealizes a sharp front and a uniform soil profile.

Method references

Frequently asked questions

Why can infiltration capacity be higher than saturated conductivity?

The wetting-front suction term adds a transient contribution early in infiltration. As cumulative infiltration grows, that contribution decays and capacity approaches K.

How do I use the Ponded Green Ampt infiltration progress calculator?

Enter Saturated hydraulic conductivity (mm/hour), Wetting-front suction magnitude (mm), Moisture deficit, Ponded infiltration duration (hours). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Ponded Green Ampt infiltration progress?

With K = 10 mm/h, ψ = 120 mm, Δθ = 0.25, and t = 2 h, A = 30 mm. Solving the relation gives F ≈ 49.0766 mm and capacity f = 10(1+30/49.0766) ≈ 16.1129 mm/h.

What does the Ponded Green Ampt infiltration progress calculator calculate?

Estimate cumulative Green–Ampt infiltration and current capacity during continuous ponding.

What assumptions apply to Ponded Green Ampt infiltration progress?

Assumes a homogeneous profile, initially uniform moisture, a sharp wetting front, and ponding from time zero. It excludes rainfall-limited preponding, layered soils, lateral flow, crusting, and changing surface storage.