How to use this calculator
Estimate bolt tension, remaining clamp, and ideal separation load in a symmetric preloaded joint with known bolt and member stiffness.
- Enter External total separating load (N), Initial preload per bolt (N), Bolt axial stiffness (N/mm), Clamped-member stiffness per bolt (N/mm), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Preloaded bolted joint load sharing explained
The applied separating load is shared across the entered bolt count. Stiffness ratio determines how much each bolt load rises and how much clamp force is lost while the joint remains closed.
Inputs, symbols, and units
F— External total separating load (N)- Force in newtons.
F0— Initial preload per bolt (N)- Initial tensile preload in each individual bolt, not the total preload of the group.
kb— Bolt axial stiffness (N/mm)- Axial force/displacement stiffness in N/mm.
km— Clamped-member stiffness per bolt (N/mm)- Clamped-member axial stiffness associated with one bolt, not the entire group.
n— Equally loaded bolts- Whole number of equally loaded identical bolts sharing the external separating load. Enter a whole number.
Formula and method
C=kb/(kb+km); before separation, Fb=F0+C·F/n and Fc=F0−(1−C)F/n.
External separating load is shared equally among n bolts. While contact remains closed, only fraction C increases bolt tension and the remainder unloads the members. Once nominal clamp reaches zero, the simplified separated joint assigns the external per-bolt load to the bolt.
A worked scenario
External total separating load (N) = 30000; Initial preload per bolt (N) = 12000; Bolt axial stiffness (N/mm) = 200000; Clamped-member stiffness per bolt (N/mm) = 600000; Equally loaded bolts = 4.
- Load per bolt after external loading: 13875 N
- Remaining clamp force per bolt: 6375 N
- Joint stiffness load fraction: 0.25
- External total load at ideal separation: 64000 N
- State: Clamped elastic joint
Four bolts share thirty kilonewtons, so the external load is 7,500 N per bolt. The stiffness ratio makes only one quarter of that increment increase bolt tension before separation.
Assumptions and edge cases
Axial concentric loading, equal preloads, linear stiffness, and no prying or embedment loss. Member stiffness is per bolt. No thread strength, fatigue, slip, tightening scatter, or joint code check is performed.
Reading the outputs
Initial preload is not subtracted from the external service load. Clamp force and bolt force change in opposite ways before contact is lost.
Frequently asked questions
Can I enter total group stiffness as km?
No. Use member stiffness associated with one equally loaded bolt.
Is preload the same as tightening torque?
No. Torque-to-preload estimation is a different uncertain model.
What happens after separation?
This simple model carries external per-bolt tension with zero remaining clamp.
How do I use the Preloaded bolted joint load sharing calculator?
Enter External total separating load (N), Initial preload per bolt (N), Bolt axial stiffness (N/mm), Clamped-member stiffness per bolt (N/mm), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Preloaded bolted joint load sharing?
External total separating load (N) = 30000; Initial preload per bolt (N) = 12000; Bolt axial stiffness (N/mm) = 200000; Clamped-member stiffness per bolt (N/mm) = 600000; Equally loaded bolts = 4. Load per bolt after external loading: 13875 N Remaining clamp force per bolt: 6375 N Joint stiffness load fraction: 0.25 External total load at ideal separation: 64000 N State: Clamped elastic joint Four bolts share thirty kilonewtons, so the external load is 7,500 N per bolt. The stiffness ratio makes only one quarter of that increment increase bolt tension before separation.
Background or definition reference: NASA Fastener Design Manual RP-1228.
Read our calculation methodology.