CalcWorldHub
Free online calculator · no signup

Pump flow rate by speed affinity law calculator

Scale a pump flow estimate when rotational speed changes and the pump geometry stays the same. Enter your values below to see the result and method.

A better way to figure it out
Clear
inputs.
∑
Clear result · useful details
Free calculatorNo signup ✓

Related calculators

These tools cover nearby questions while keeping this page focused on its own calculation.

Browse engineering calculators →

Pump flow rate by speed affinity law calculator — Reference flow (L/s), Reference speed (rpm), New speed (rpm) and calculation method
Pump flow rate by speed affinity law calculator: inputs and calculation method.

How to use this calculator

Scale a pump flow estimate when rotational speed changes and the pump geometry stays the same.

  1. Enter Reference flow (L/s), Reference speed (rpm), New speed (rpm). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Free calculator guide

Define the component and operating point

For the same rotodynamic pump at similar operating conditions, flow scales linearly with rotational speed. This affinity-law estimate does not solve the installation's system curve.

Inputs and units

Enter a baseline flow and its pump speed plus a positive target speed. Keep the flow unit and pump configuration the same.

Design equation and example

Q₂ = Q₁(N₂ ÷ N₁)

A 10 L/s reference flow at 1,500 rpm scales to 12 L/s at 1,800 rpm.

Intermediate values are kept unrounded; the displayed result is rounded for readability.

Applying the result in a system

The value is an ideal scaled flow for the same pump, not the final system operating point; compare it with the pump curve and system resistance.

Assumptions and limitations

Ideal affinity-law estimate for the same pump and fluid; system resistance and efficiency can shift the operating point.

Frequently asked questions

Which measurements belong in the pump flow rate by speed affinity law?

Use a baseline flow and paired reference speed, then a positive target speed for the same pump.

What can make a real installation differ from this pump flow rate by speed affinity law estimate?

Ideal affinity-law estimate for the same pump and fluid; system resistance and efficiency can shift the operating point.

How do I use the Pump flow rate by speed affinity law calculator?

Enter Reference flow (L/s), Reference speed (rpm), New speed (rpm). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Pump flow rate by speed affinity law?

Q₂ = Q₁(N₂ ÷ N₁) A 10 L/s reference flow at 1,500 rpm scales to 12 L/s at 1,800 rpm. Intermediate values are kept unrounded; the displayed result is rounded for readability.

What does the Pump flow rate by speed affinity law calculator calculate?

Scale a pump flow estimate when rotational speed changes and the pump geometry stays the same.