How to use this calculator
Estimate peak runoff for a small catchment using rainfall intensity and a lumped runoff coefficient.
- Enter Runoff coefficient, Design rainfall intensity (mm/hour), Catchment area (hectares). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Rational method peak runoff explained
With C dimensionless, intensity in mm/h, and area in hectares, Q = C·i·A/360 gives an estimated peak flow in m³/s for the chosen design duration.
Inputs, symbols, and units
c— Runoff coefficient- Runoff coefficient.
i— Design rainfall intensity (mm/hour)- Design rainfall intensity (mm/hour).
a— Catchment area (hectares)- Catchment area (hectares).
Formula and method
c*i*a/360
Here C is a unitless runoff coefficient, i is design intensity in mm/h, and A is area in hectares. Rainfall duration must relate appropriately to concentration time and local design practice.
A worked scenario
Runoff coefficient = 0.6; Design rainfall intensity (mm/hour) = 50; Catchment area (hectares) = 5.
- Rational method peak runoff: 0.416667 m³/s
For C = 0.6, i = 50 mm/h, and A = 5 ha, the estimated peak is 0.4167 m³/s; duration selection determines whether the intensity is appropriate.
Assumptions and edge cases
Rainfall duration must relate appropriately to concentration time and local design practice. No hydrograph or storage routing is computed.
Frequently asked questions
Is daily rainfall depth the right intensity?
No, use intensity for the relevant design duration.
Does it give storm runoff volume?
No, it estimates a peak flow.
Is the coefficient universal?
No, select it for the catchment and design context.
How do I use the Rational method peak runoff calculator?
Enter Runoff coefficient, Design rainfall intensity (mm/hour), Catchment area (hectares). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Rational method peak runoff?
Runoff coefficient = 0.6; Design rainfall intensity (mm/hour) = 50; Catchment area (hectares) = 5. Rational method peak runoff: 0.416667 m³/s For C = 0.6, i = 50 mm/h, and A = 5 ha, the estimated peak is 0.4167 m³/s; duration selection determines whether the intensity is appropriate.
Read our calculation methodology.