How to use this calculator
Find the conjugate depth required to balance momentum across an ideal rectangular hydraulic jump and quantify the associated energy dissipation.
- Enter Channel width (m), Discharge (m³/s), Upstream supercritical depth (m). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Rectangular hydraulic jump conjugate depth and loss explained
A numerical walkthrough
Channel width (m) = 4; Discharge (m³/s) = 10; Upstream supercritical depth (m) = 0.5.
- Conjugate downstream depth: 1.366104 m
- Specific energy dissipated: 0.237791 m
- Upstream Froude number: 2.258004
- Dissipated hydraulic power: 23.319351 kW
A 4 m wide channel carrying 10 m³/s at 0.5 m depth has velocity 5 m/s and Fr≈2.258. The conjugate depth is about 1.367 m.
The model behind the numbers
Fr1=Q/(by1√(gy1)); y2/y1=[√(1+8Fr1²)−1]/2; ΔE=(y2−y1)³/(4y1y2).
The jump conserves momentum under the stated assumptions, not specific energy. Tailwater must support the calculated conjugate depth for a stationary jump near the assumed section.
What to enter
b— Channel width (m)- Constant rectangular width through the ideal jump.
Q— Discharge (m³/s)- Steady flow passing through the jump.
y1— Upstream supercritical depth (m)- Depth immediately before the jump; it must have Froude number greater than one.
Interpreting the result
Horizontal prismatic rectangular channel, hydrostatic sections outside the jump, negligible external resistance over its short length and unit momentum correction factors. Educational model; this is not a code-compliant design check.
Reading the outputs
Conjugate depth and lost head are m, Fr is dimensionless and dissipation power is kW for water at 1000 kg/m³.
Frequently asked questions
Will a jump form exactly at the chosen section?
Not necessarily. Tailwater, channel geometry and controls determine its location.
Why reject Fr below one?
A hydraulic jump connects supercritical flow to a deeper subcritical state; a subcritical upstream state does not fit this mechanism.
Does the lost head disappear from the water?
It is dissipated through turbulence and heat rather than conserved as mechanical head.
How do I use the Rectangular hydraulic jump conjugate depth and loss calculator?
Enter Channel width (m), Discharge (m³/s), Upstream supercritical depth (m). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Rectangular hydraulic jump conjugate depth and loss?
Channel width (m) = 4; Discharge (m³/s) = 10; Upstream supercritical depth (m) = 0.5. Conjugate downstream depth: 1.366104 m Specific energy dissipated: 0.237791 m Upstream Froude number: 2.258004 Dissipated hydraulic power: 23.319351 kW A 4 m wide channel carrying 10 m³/s at 0.5 m depth has velocity 5 m/s and Fr≈2.258. The conjugate depth is about 1.367 m.
Background or definition reference: USACE HEC-RAS Hydraulic Reference Manual.
Reference access note: The linked HEC-RAS reference PDF was not retrievable during this review. The stated equation and numerical example were checked independently; verify against current official hydraulic guidance before design use.
Read our calculation methodology.