CalcWorldHub
Free online calculator · no signup

Root-zone irrigation depletion trigger calculator

Estimate how much plant-available root-zone water can be depleted before a chosen irrigation trigger.

4,000 tools
Root-zone irrigation depletion trigger calculator — Volumetric water content at field capacity (m³/m³), Volumetric water content at wilting point (m³/m³), Effective rooting depth (m) and calculation method
Root-zone irrigation depletion trigger calculator: inputs and calculation method.

How to use this calculator

Estimate how much plant-available root-zone water can be depleted before a chosen irrigation trigger.

  1. Enter Volumetric water content at field capacity (m³/m³), Volumetric water content at wilting point (m³/m³), Effective rooting depth (m), Allowable depletion fraction p, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Agriculture calculation

How this calculation works

The trigger compares current root-zone depletion with readily available water. Total available water comes from the field-capacity and wilting-point difference across the active root depth; a selected depletion fraction defines the threshold before water stress is expected under the chosen method.

Inputs and units

fc — Volumetric water content at field capacity (m³/m³)
Enter a fraction such as 0.30, not a percentage.
wp — Volumetric water content at wilting point (m³/m³)
Use the same volumetric fraction convention as field capacity.
depth — Effective rooting depth (m)
Root-zone depth represented by the soil water estimate.
p — Allowable depletion fraction p
Selected share of total available water that may be depleted before the trigger.
depletion — Current root-zone depletion (mm)
Water deficit from field capacity across the represented root zone.

Formula

Displayed formula

TAW = 1000(θFC − θWP)Zr; RAW = p × TAW; water remaining before trigger = RAW − Dr. Irrigation is due when Dr ≥ RAW.

Method

Enter volumetric water contents as fractions from 0 to 1, rooting depth in metres, a depletion fraction p from 0 to 1, and current depletion Dr in millimetres. The calculator reports TAW, the selected trigger RAW, remaining buffer, and trigger status.

Worked example

With θFC 0.30, θWP 0.12, a 0.60 m root zone, p = 0.45, and 40 mm current depletion, TAW = 108 mm, RAW = 48.6 mm, leaving an 8.6 mm buffer.

Assumptions and limits

This is a root-zone water-storage estimate, not a crop-specific prescription. Field capacity, wilting point, effective rooting depth, and depletion fraction vary by soil, crop, growth stage, salinity, and management. It omits rainfall, capillary rise, root growth, and application losses.

Frequently asked questions

What is readily available water?

It is the selected fraction of total available root-zone water that may be depleted before the method expects crop water stress.

Should I enter 30% as 30 or 0.30?

Enter 0.30 for a volumetric water content of 30%.

Does reaching the trigger tell me the irrigation depth to apply?

No. It marks a depletion threshold. Net refill depth, system efficiency, rainfall, and scheduling constraints need separate decisions.

Can the same p value be used for every crop?

No. The depletion fraction depends on crop, evaporative demand, rooting conditions, and management assumptions.

How do I use the Root-zone irrigation depletion trigger calculator?

Enter Volumetric water content at field capacity (m³/m³), Volumetric water content at wilting point (m³/m³), Effective rooting depth (m), Allowable depletion fraction p, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.