How to use this calculator
Calculate a membrane-feed silt density index from initial and final filter test times.
- Enter Initial time to collect 500 mL, tᵢ (s), Final time to collect 500 mL, t𝒇 (s), Test duration, T (min). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The silt density index is a fouling-potential indicator based on how the time to collect a fixed filtrate volume changes during a constant-pressure test. This calculator applies the stated test-duration equation to the two measured collection times.
Inputs and units
initialTime— Initial time to collect 500 mL, tᵢ (s)- Record the initial 500 mL collection time in seconds.
finalTime— Final time to collect 500 mL, t𝒇 (s)- Record the collection time after the test interval.
duration— Test duration, T (min)- Elapsed time between initial and final measurements.
Formula
SDIₜ = (1 − tᵢ / t𝒇) × 100 / T.
Method
Divide the initial filtrate collection time by the final time, convert the fractional loss in filtration rate to a percentage, and divide by test duration in minutes.
Worked example
With an initial time of 25 s, a final time of 50 s, and a 15-minute test, filtration-rate loss is 50% and SDI₁₅ = 3.33.
Assumptions and limits
Use initial and final times measured for the same filtrate volume under the same prescribed filter and pressure conditions. The equation does not replace the applicable test method; report the test duration and conditions with the result.
Frequently asked questions
What does SDI indicate?
It is an empirical indicator of particulate fouling potential for membrane feed water.
Why must the two times use the same filtrate volume?
The calculation compares filtration rate before and after the test, so the collection volumes and test conditions must match.
Does SDI directly predict membrane life?
No. It is a feed-water fouling indicator and does not model membrane operation, pretreatment, or service life.
How do I use the Silt Density Index (SDI) Calculator?
Enter Initial time to collect 500 mL, tᵢ (s), Final time to collect 500 mL, t𝒇 (s), Test duration, T (min). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Silt Density Index (SDI)?
With an initial time of 25 s, a final time of 50 s, and a 15-minute test, filtration-rate loss is 50% and SDI₁₅ = 3.33.
Reference: DuPont IntegraTec process and design manual SDI test equation. See our calculation methodology.