CalcWorldHub
Free online calculator · no signup

Steady state polynomial command tracking error calculator

Predict whether an already stable feedback loop can follow a step, ramp or constant-acceleration command with finite error.

4,000 tools
Steady state polynomial command tracking error calculator — Loop integrator count, Command polynomial order, Command scale and calculation method
Steady state polynomial command tracking error calculator: inputs and calculation method.

How to use this calculator

Predict whether an already stable feedback loop can follow a step, ramp or constant-acceleration command with finite error.

  1. Enter Loop integrator count, Command polynomial order, Command scale, Low-frequency error constant. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Steady state polynomial command tracking error explained

Predict whether an already stable feedback loop can follow a step, ramp or constant-acceleration command with finite error.

Steady-state error0.4command units
Steady-state error: 0.4 command units in the worked scenario.

How the calculation works

For r=A tⁿ/n!, E(s)=A/[sⁿ⁺¹(1+L(s))]. With L≈k/sᵐ, final error is zero if m>n, A/k if m=n>0, and A/(1+k) if m=n=0.

Use the low-frequency error constant with the units implied by the selected loop type. The final-value theorem requires closed-loop stability first.

Set up the calculation

type — Loop integrator count
Number of poles at the origin in the open loop. Enter a whole number.
order — Command polynomial order
Zero for step, one for ramp, two for parabolic. Enter a whole number.
A — Command scale
Step height, ramp slope, or parabolic acceleration.
gain — Low-frequency error constant
Positive limit of s to the type times the open-loop transfer.

Limits of this model

Does not test stability. Commands whose order exceeds the loop type have unbounded error and are rejected.

Check this example

Loop integrator count = 1; Command polynomial order = 1; Command scale = 2; Low-frequency error constant = 5.

  • Steady-state error: 0.4 command units
  • Loop type: 1 integrators

A type-one loop with velocity constant five follows a ramp of slope two with a finite constant offset.

Reading the outputs

Error is signed with the command scale; the type metric confirms the number of open-loop integrators.

Frequently asked questions

Does adding an integrator always help?

It improves low-frequency tracking only if stability is preserved.

What is a parabolic command here?

The reference is A t²/2, so A is its acceleration.

Can this handle nonlinear saturation?

No. Saturation can invalidate linear steady-state error predictions.

How do I use the Steady state polynomial command tracking error calculator?

Enter Loop integrator count, Command polynomial order, Command scale, Low-frequency error constant. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Steady state polynomial command tracking error?

Loop integrator count = 1; Command polynomial order = 1; Command scale = 2; Low-frequency error constant = 5. Steady-state error: 0.4 command units Loop type: 1 integrators A type-one loop with velocity constant five follows a ramp of slope two with a finite constant offset.