How to use this calculator
Infer moisture in an upstream wet-steam sample from a valid downstream superheated throttling-calorimeter state.
- Enter Upstream saturated-liquid enthalpy (kJ/kg), Upstream latent enthalpy (kJ/kg), Downstream saturated-vapor enthalpy (kJ/kg), Approximate downstream vapor cp (kJ/kg/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Steam throttling calorimeter dryness fraction explained
Use Upstream saturated-liquid enthalpy (kJ/kg) with Upstream latent enthalpy (kJ/kg) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
Inputs, symbols, and units
hf1— Upstream saturated-liquid enthalpy (kJ/kg)- Upstream saturated-liquid enthalpy (kJ/kg). Enter the value for this state; the units shown are used without an unstated conversion.
hfg1— Upstream latent enthalpy (kJ/kg)- Upstream latent enthalpy (kJ/kg). Enter the value for this state; the units shown are used without an unstated conversion.
hg2— Downstream saturated-vapor enthalpy (kJ/kg)- Downstream saturated-vapor enthalpy (kJ/kg). Enter the value for this state; the units shown are used without an unstated conversion.
cpv— Approximate downstream vapor cp (kJ/kg/K)- Approximate downstream vapor cp (kJ/kg/K). Enter the value for this state; the units shown are used without an unstated conversion.
T2— Measured downstream temperature (°C)- Measured downstream temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
Ts2— Downstream saturation temperature (°C)- Downstream saturation temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
Formula and method
hup=hf,up+x hfg,up=hg,down+cp,v(Tdown−Tsat,down).
Throttling preserves specific enthalpy when heat and kinetic changes are negligible. The downstream vapor enthalpy is approximated from its saturation value and measured superheat.
A worked scenario
Upstream saturated-liquid enthalpy (kJ/kg) = 762; Upstream latent enthalpy (kJ/kg) = 2015; Downstream saturated-vapor enthalpy (kJ/kg) = 2676; Approximate downstream vapor cp (kJ/kg/K) = 2.05; Measured downstream temperature (°C) = 130; Downstream saturation temperature (°C) = 100.
- Upstream vapor mass fraction: 98.039702 %
- Isenthalpic sample enthalpy: 2737.5 kJ/kg
- Upstream moisture fraction: 1.960298 %
Steam throttled to an outlet 30 K above its 100 °C saturation temperature has estimated outlet enthalpy 2,737.5 kJ/kg. Against upstream hf=762 and hfg=2,015 kJ/kg, that implies 98.0397% inlet dryness and 1.9603% moisture.
Assumptions and edge cases
Requires verified saturation data and a genuinely superheated outlet. The constant vapor cp approximation must be adequate over the superheat interval.
Reading the outputs
Dryness is vapor mass percent, moisture is the complementary liquid mass percent and sample enthalpy is kJ/kg.
Frequently asked questions
Why reject a saturated outlet?
Temperature and pressure alone do not identify enthalpy inside the two-phase region.
Is dryness a volume fraction?
No. It is vapor mass fraction.
What if the computed quality exceeds one?
The sample or property data are inconsistent with upstream wet steam under this approximation.
How do I use the Steam throttling calorimeter dryness fraction calculator?
Enter Upstream saturated-liquid enthalpy (kJ/kg), Upstream latent enthalpy (kJ/kg), Downstream saturated-vapor enthalpy (kJ/kg), Approximate downstream vapor cp (kJ/kg/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Steam throttling calorimeter dryness fraction?
Upstream saturated-liquid enthalpy (kJ/kg) = 762; Upstream latent enthalpy (kJ/kg) = 2015; Downstream saturated-vapor enthalpy (kJ/kg) = 2676; Approximate downstream vapor cp (kJ/kg/K) = 2.05; Measured downstream temperature (°C) = 130; Downstream saturation temperature (°C) = 100. Upstream vapor mass fraction: 98.039702 % Isenthalpic sample enthalpy: 2737.5 kJ/kg Upstream moisture fraction: 1.960298 % Steam throttled to an outlet 30 K above its 100 °C saturation temperature has estimated outlet enthalpy 2,737.5 kJ/kg. Against upstream hf=762 and hfg=2,015 kJ/kg, that implies 98.0397% inlet dryness and 1.9603% moisture.
Background or definition reference: DOE Fundamentals Handbook: thermodynamic energy balances.
Read our calculation methodology.