How to use this calculator
Estimate saturated-steam consumption from a process heat duty and useful enthalpy release per kilogram.
- Enter Process heat duty (kW), Useful steam enthalpy release (kJ/kg). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
A steam-side heat balance relates thermal duty to steam mass flow and the enthalpy drop used by the process. For condensing saturated steam, latent heat can approximate the useful release only when condensate leaves at the saturation condition and other heat terms are negligible.
Inputs and units
heatDuty— Process heat duty (kW)- Thermal load delivered to the process, in kilowatts.
enthalpyRelease— Useful steam enthalpy release (kJ/kg)- Steam enthalpy decrease available to the process per kilogram, from appropriate steam tables or a process balance.
Formula
ṁ = Q̇ / Δh; for Q̇ in kW and Δh in kJ/kg, ṁ (kg/h) = 3,600 Q̇ / Δh.
Method
Enter heat duty in kilowatts and the steam enthalpy released per kilogram in kilojoules per kilogram. Use a steam-table value or a process-specific enthalpy difference appropriate to pressure, steam quality, condensate state, and heat loss.
Worked example
At 120 kW and 2,200 kJ/kg of useful enthalpy release, estimated steam use is 196.36 kg/h, or 0.05455 kg/s.
Assumptions and limits
This is a steady heat-duty estimate. It does not size warm-up load, account for distribution losses, control behavior, condensate subcooling unless reflected in the entered enthalpy drop, or select pressure and heat-exchanger area. Do not assume one universal latent heat.
Frequently asked questions
Which enthalpy value should I enter?
Use the enthalpy drop actually available between inlet steam and outlet condensate for the process conditions.
Can I enter latent heat?
Yes, when the process uses saturated steam by condensation and the condensate leaves near saturation at the same pressure; otherwise use an effective enthalpy drop.
Does this include startup steam?
No. Startup or warm-up demand is a separate transient load.
How do I use the Steam Mass Flow from Heat Duty Calculator?
Enter Process heat duty (kW), Useful steam enthalpy release (kJ/kg). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Steam Mass Flow from Heat Duty?
At 120 kW and 2,200 kJ/kg of useful enthalpy release, estimated steam use is 196.36 kg/h, or 0.05455 kg/s.
Reference: Spirax Sarco steam-consumption method connecting heat duty and useful enthalpy release. See our calculation methodology.