How to use this calculator
Separate high-pressure expansion, reheating and low-pressure expansion to check the total heat and work of a reheat steam plant.
- Enter Condenser exit h1 (kJ/kg), Pump exit h2 (kJ/kg), High-pressure turbine inlet h3 (kJ/kg), High-pressure turbine exit h4 (kJ/kg), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Reheat steam cycle enthalpy balance explained
A single-reheat steam cycle has two turbine enthalpy drops and two heat-input sections. Add both turbine outputs, subtract pump work, and divide net work by boiler-plus-reheater heat input; reheating is an external energy input in this balance.
Inputs, symbols, and units
h1— Condenser exit h1 (kJ/kg)- Specific enthalpy leaving the condenser and entering the pump, in kJ/kg.
h2— Pump exit h2 (kJ/kg)- Specific enthalpy leaving the pump; its increase over h1 is the required pump work per kilogram.
h3— High-pressure turbine inlet h3 (kJ/kg)- Specific enthalpy entering the high-pressure turbine after the boiler.
h4— High-pressure turbine exit h4 (kJ/kg)- High-pressure turbine exit enthalpy before reheating.
h5— Reheater exit h5 (kJ/kg)- Reheater exit enthalpy entering the low-pressure turbine.
h6— Low-pressure turbine exit h6 (kJ/kg)- Low-pressure turbine exit enthalpy before heat rejection, from a consistent steam property state.
Formula and method
wt=(h₃−h₄)+(h₅−h₆), qin=(h₃−h₂)+(h₅−h₄), wp=h₂−h₁.
Both turbine sections carry the same mass flow. Add the two enthalpy drops and count reheater energy as external heat rather than treating it as recovered heat.
A worked scenario
Condenser exit h1 (kJ/kg) = 190; Pump exit h2 (kJ/kg) = 200; High-pressure turbine inlet h3 (kJ/kg) = 3400; High-pressure turbine exit h4 (kJ/kg) = 2900; Reheater exit h5 (kJ/kg) = 3500; Low-pressure turbine exit h6 (kJ/kg) = 2400.
- Cycle efficiency: 41.842105 %
- Net specific work: 1590 kJ/kg
- Reheat duty: 600 kJ/kg
- Total heat input: 3800 kJ/kg
A turbine first expands from 3,400 to 2,900 kJ/kg, reheats to 3,500 and exits at 2,400. Including the 10 kJ/kg pump input yields 1,590 kJ/kg net work and 41.8421% efficiency; the reheat section supplies 600 kJ/kg.
Assumptions and edge cases
Single reheat, no bleeds or pressure-loss corrections. This implementation requires positive turbine expansion work, boiler duty and reheat duty, so the zero-reheat limit is outside its accepted input domain. State enthalpies must be supplied from a consistent property calculation.
Reading the outputs
Reports cycle efficiency, net shaft work per kilogram, reheat duty and combined boiler-plus-reheater duty.
Frequently asked questions
Is reheat heat free?
No. It is included in total heat input.
Can the low-pressure exit be wet?
Yes, provided h6 is a valid enthalpy for that state.
What changes with steam extraction?
Section mass flows differ; use the open-heater balance or a complete plant model.
How do I use the Reheat steam cycle enthalpy balance calculator?
Enter Condenser exit h1 (kJ/kg), Pump exit h2 (kJ/kg), High-pressure turbine inlet h3 (kJ/kg), High-pressure turbine exit h4 (kJ/kg), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Reheat steam cycle enthalpy balance?
Condenser exit h1 (kJ/kg) = 190; Pump exit h2 (kJ/kg) = 200; High-pressure turbine inlet h3 (kJ/kg) = 3400; High-pressure turbine exit h4 (kJ/kg) = 2900; Reheater exit h5 (kJ/kg) = 3500; Low-pressure turbine exit h6 (kJ/kg) = 2400. Cycle efficiency: 41.842105 % Net specific work: 1590 kJ/kg Reheat duty: 600 kJ/kg Total heat input: 3800 kJ/kg A turbine first expands from 3,400 to 2,900 kJ/kg, reheats to 3,500 and exits at 2,400. Including the 10 kJ/kg pump input yields 1,590 kJ/kg net work and 41.8421% efficiency; the reheat section supplies 600 kJ/kg.
Background or definition reference: IIT NPTEL reheat Rankine cycle.
Read our calculation methodology.