CalcWorldHub
Free online calculator · no signup

Regenerative Rankine open feedwater heater calculator

Find the steam extraction fraction and cycle efficiency for one direct-contact feedwater heater with two pumps.

4,000 tools
Regenerative Rankine open feedwater heater calculator — Turbine inlet enthalpy (kJ/kg), Extraction steam enthalpy (kJ/kg), Final turbine exit enthalpy (kJ/kg) and calculation method
Regenerative Rankine open feedwater heater calculator: inputs and calculation method.

How to use this calculator

Find the steam extraction fraction and cycle efficiency for one direct-contact feedwater heater with two pumps.

  1. Enter Turbine inlet enthalpy (kJ/kg), Extraction steam enthalpy (kJ/kg), Final turbine exit enthalpy (kJ/kg), Condenser liquid enthalpy (kJ/kg), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Regenerative Rankine open feedwater heater explained

Apply the mass and energy balance of one adiabatic open feedwater heater, then account for the extraction fraction in turbine and pump work.

Extraction steam fraction19.3858%
Extraction steam fraction: 19.385797 % in the worked scenario.

How the calculation works

y=(hf−hp)/(hb−hp); wt=(hi−hb)+(1−y)(hb−he); wp=(1−y)(hp−hc)+(hbp−hf).

Normalize the boiler steam flow to one kilogram. Only the fraction 1−y passes through the low-pressure turbine, condenser and first pump; the second pump carries the full boiler flow.

Set up the calculation

hi — Turbine inlet enthalpy (kJ/kg)
Specific enthalpy of steam entering the turbine, per kg boiler flow.
hb — Extraction steam enthalpy (kJ/kg)
Specific enthalpy of the extraction steam entering the open heater.
he — Final turbine exit enthalpy (kJ/kg)
Specific enthalpy at the final turbine exit before the condenser.
hc — Condenser liquid enthalpy (kJ/kg)
Specific enthalpy of condensate leaving the condenser.
hp — Low-pressure pump outlet enthalpy (kJ/kg)
Specific enthalpy after the low-pressure pump and before the open heater.
hf — Open-heater mixed outlet enthalpy (kJ/kg)
Specific enthalpy of the mixed liquid leaving the open heater.
hbp — Boiler-feed pump outlet enthalpy (kJ/kg)
Specific enthalpy after the boiler-feed pump and before the boiler.

Limits of this model

One adiabatic open heater and one extraction pressure. No drain coolers, cascaded heaters, leakage or finite pressure drops are modeled.

Check this example

Turbine inlet enthalpy (kJ/kg) = 3400; Extraction steam enthalpy (kJ/kg) = 2800; Final turbine exit enthalpy (kJ/kg) = 2200; Condenser liquid enthalpy (kJ/kg) = 190; Low-pressure pump outlet enthalpy (kJ/kg) = 195; Open-heater mixed outlet enthalpy (kJ/kg) = 700; Boiler-feed pump outlet enthalpy (kJ/kg) = 710.

  • Extraction steam fraction: 19.385797 %
  • Cycle efficiency: 39.764108 %
  • Net specific work: 1069.654511 kJ/kg
  • Boiler heat: 2690 kJ/kg

To raise the pumped condensate from 195 to 700 kJ/kg using 2,800 kJ/kg extraction steam, the open heater diverts 19.3858% of the main steam flow. That bleed reduces low-pressure turbine mass flow; total net work is 1,069.65 kJ/kg main flow.

Reading the outputs

Extraction fraction is percent of boiler flow. Efficiency uses both pump works; net work and heat input are per kilogram of boiler steam.

Frequently asked questions

Why is low-pressure turbine work multiplied by 1−y?

Extracted steam leaves before that turbine section.

Can heater outlet enthalpy exceed extraction enthalpy?

Not for this adiabatic two-stream mixture; that input set is rejected.

Is extraction percentage based on condenser flow?

No. It is based on total boiler flow.

How do I use the Regenerative Rankine open feedwater heater calculator?

Enter Turbine inlet enthalpy (kJ/kg), Extraction steam enthalpy (kJ/kg), Final turbine exit enthalpy (kJ/kg), Condenser liquid enthalpy (kJ/kg), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Regenerative Rankine open feedwater heater?

Turbine inlet enthalpy (kJ/kg) = 3400; Extraction steam enthalpy (kJ/kg) = 2800; Final turbine exit enthalpy (kJ/kg) = 2200; Condenser liquid enthalpy (kJ/kg) = 190; Low-pressure pump outlet enthalpy (kJ/kg) = 195; Open-heater mixed outlet enthalpy (kJ/kg) = 700; Boiler-feed pump outlet enthalpy (kJ/kg) = 710. Extraction steam fraction: 19.385797 % Cycle efficiency: 39.764108 % Net specific work: 1069.654511 kJ/kg Boiler heat: 2690 kJ/kg To raise the pumped condensate from 195 to 700 kJ/kg using 2,800 kJ/kg extraction steam, the open heater diverts 19.3858% of the main steam flow.