Symmetric Fabry Perot cavity linewidth calculator

Estimate free spectral range, exact ideal Airy FWHM, and finesse for identical lossless mirrors.

4,000 tools
Symmetric Fabry Perot cavity linewidth calculator — Mirror separation (mm), Uniform cavity refractive index, Power reflectivity of each identical mirror and calculation method
Symmetric Fabry Perot cavity linewidth calculator: inputs and calculation method.

How to use this calculator

Estimate free spectral range, exact ideal Airy FWHM, and finesse for identical lossless mirrors.

  1. Enter Mirror separation (mm), Uniform cavity refractive index, Power reflectivity of each identical mirror. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Symmetric Fabry Perot cavity linewidth explained

Free spectral range14989622900Hz
Free spectral range: 14989622900 Hz in the worked scenario.

How the calculation works

FSR=c/(2nL); Airy FWHM=FSR·(2/π)asin((1−R)/(2√R))

Mirror spacing determines the longitudinal round-trip phase and free spectral range c/(2nL). The exact Airy half-power condition gives a phase offset through an arcsine, converted here to full frequency linewidth. Finesse is free spectral range divided by that linewidth.

Set up the calculation

l — Mirror separation (mm)
Mirror separation (mm).
n — Uniform cavity refractive index
Uniform cavity refractive index.
r — Power reflectivity of each identical mirror
Power reflectivity of each identical mirror.

Limits of this model

Normal incidence, equal mirror power reflectivity, no absorption or dispersion. The lower reflectivity bound ensures a half-maximum linewidth exists between resonances.

Check this example

Mirror separation (mm) = 10; Uniform cavity refractive index = 1; Power reflectivity of each identical mirror = 0.9.

  • Free spectral range: 14989622900 Hz
  • Ideal Airy FWHM: 503177076.154685 Hz
  • Finesse: 29.78995588

Interpreting the result

The free spectral range is the spacing between adjacent longitudinal resonances. The Airy linewidth is the width of one resonance and depends on mirror reflectivity; it is not the same quantity as the resonance spacing.

Frequently asked questions

Is reflectivity an amplitude coefficient?

No, enter power reflectivity.

Why use an arcsine linewidth?

It retains the exact ideal Airy half-maximum condition rather than only a high-finesse approximation.

Does refractive-index dispersion affect FSR?

Yes, a group-index model is needed when dispersion matters.

How do I use the Symmetric Fabry Perot cavity linewidth calculator?

Enter Mirror separation (mm), Uniform cavity refractive index, Power reflectivity of each identical mirror. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Symmetric Fabry Perot cavity linewidth?

Mirror separation (mm) = 10; Uniform cavity refractive index = 1; Power reflectivity of each identical mirror = 0.9. Free spectral range: 14989622900 Hz Ideal Airy FWHM: 503177076.154685 Hz Finesse: 29.78995588