How to use this calculator
Fit a three-term transparent-band Cauchy dispersion model from three measured wavelength-index pairs.
- Enter Three vacuum wavelengths (nm), Measured phase indices, Target wavelength (nm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Three line Cauchy dispersion fit explained
A numerical walkthrough
Three vacuum wavelengths (nm) = [450, 550, 650]; Measured phase indices = [1.525, 1.519, 1.515]; Target wavelength (nm) = 600.
- Fitted target index: 1.5168
- Cauchy A coefficient: 1.503137
- Cauchy B coefficient: 0.00555 µm²
- Cauchy C coefficient: -0.000227 µm⁴
Measured indices 1.525,1.519,1.515 at 450,550,650 nm predict an intermediate index at 600 nm.
The model behind the numbers
n(λ)=A+B/λ²+C/λ⁴, λ in µm; solve the three linear coefficient equations.
Exactly three data pairs determine the coefficients without residual degrees of freedom. Interpolation between measured lines is usually more defensible than extrapolation.
What to enter
waves— Three vacuum wavelengths (nm)- Distinct measured wavelengths in the transparent band. Use comma-separated values in the stated order.
indices— Measured phase indices- Index measurements paired with the wavelength list. Use comma-separated values in the stated order.
target— Target wavelength (nm)- Wavelength where the fitted model is evaluated.
Interpreting the result
An empirical local fit, not a resonance model. Three points cannot estimate measurement uncertainty or validate behavior near absorption.
Reading the outputs
Target index is dimensionless. Coefficients carry the squared and fourth-power micrometre units needed by the fitted equation.
Frequently asked questions
Does a perfect three-point fit prove the model?
No. Three coefficients can interpolate three values even when the model is poor elsewhere.
Can I use repeated wavelengths?
No. They make the coefficient system singular.
Why report coefficient units?
The numerical values of B and C depend on the wavelength unit.
How do I use the Three line Cauchy dispersion fit calculator?
Enter Three vacuum wavelengths (nm), Measured phase indices, Target wavelength (nm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Three line Cauchy dispersion fit?
Three vacuum wavelengths (nm) = [450, 550, 650]; Measured phase indices = [1.525, 1.519, 1.515]; Target wavelength (nm) = 600. Fitted target index: 1.5168 Cauchy A coefficient: 1.503137 Cauchy B coefficient: 0.00555 µm² Cauchy C coefficient: -0.000227 µm⁴ Measured indices 1.525,1.519,1.515 at 450,550,650 nm predict an intermediate index at 600 nm.
Background or definition reference: SCHOTT optical glass technical information.
Read our calculation methodology.