Three stream parallel heat exchanger outlet temperatures calculator

Predict all three outlet temperatures when three co-current streams exchange heat through pairwise conductances.

4,000 tools
Three stream parallel heat exchanger outlet temperatures calculator — Stream 1 heat-capacity rate (W/K), Stream 2 heat-capacity rate (W/K), Stream 3 heat-capacity rate (W/K) and calculation method
Three stream parallel heat exchanger outlet temperatures calculator: inputs and calculation method.

How to use this calculator

Predict all three outlet temperatures when three co-current streams exchange heat through pairwise conductances.

  1. Enter Stream 1 heat-capacity rate (W/K), Stream 2 heat-capacity rate (W/K), Stream 3 heat-capacity rate (W/K), Total stream 1 to 2 conductance (W/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Three stream parallel heat exchanger outlet temperatures explained

Stream 1 outlet temperature67.804°C
Stream 1 outlet temperature: 67.803995 °C in the worked scenario.

How the calculation works

Ci dTi/ds=Σj UAij(Tj−Ti), 0≤s≤1; T(1)=exp(−C⁻¹G)T(0).

The normalized axial coordinate puts each total pair conductance into a coupled three-temperature balance. Integrate with fourth-order Runge–Kutta and report the combined energy residual.

Set up the calculation

C1 — Stream 1 heat-capacity rate (W/K)
Stream 1 heat-capacity rate (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
C2 — Stream 2 heat-capacity rate (W/K)
Stream 2 heat-capacity rate (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
C3 — Stream 3 heat-capacity rate (W/K)
Stream 3 heat-capacity rate (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
U12 — Total stream 1 to 2 conductance (W/K)
Total stream 1 to 2 conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
U13 — Total stream 1 to 3 conductance (W/K)
Total stream 1 to 3 conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
U23 — Total stream 2 to 3 conductance (W/K)
Total stream 2 to 3 conductance (W/K). Enter the value for this state; the units shown are used without an unstated conversion.
T1 — Stream 1 inlet temperature (°C)
Stream 1 inlet temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
T2 — Stream 2 inlet temperature (°C)
Stream 2 inlet temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
T3 — Stream 3 inlet temperature (°C)
Stream 3 inlet temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.

Limits of this model

All three streams move in the same direction, constant capacity rates and uniformly distributed conductances, no axial conduction, external loss or phase change.

Check this example

Stream 1 heat-capacity rate (W/K) = 1000; Stream 2 heat-capacity rate (W/K) = 800; Stream 3 heat-capacity rate (W/K) = 1200; Total stream 1 to 2 conductance (W/K) = 500; Total stream 1 to 3 conductance (W/K) = 300; Total stream 2 to 3 conductance (W/K) = 200; Stream 1 inlet temperature (°C) = 100; Stream 2 inlet temperature (°C) = 20; Stream 3 inlet temperature (°C) = 40.

  • Stream 1 outlet temperature: 67.803995 °C
  • Stream 2 outlet temperature: 48.440284 °C
  • Stream 3 outlet temperature: 47.869815 °C
  • Total stream energy residual: 8.73114914e-11 W

Three parallel streams enter at 100, 20 and 40 °C with capacity rates 1,000, 800 and 1,200 W/K. The stated pair conductances bring them to 67.8040, 48.4403 and 47.8698 °C; their capacity-weighted energy changes sum to zero.

Reading the outputs

Outlet temperatures are °C and the signed capacity-weighted energy residual is W. Each outlet remains within the inlet temperature envelope in this passive model.

Frequently asked questions

Can one pair be thermally separated?

Yes. Set that pair conductance to zero; other coupling paths can still exchange energy indirectly.

Why is one two-stream effectiveness insufficient?

Each local stream temperature depends on both neighboring temperatures along the entire exchanger.

Can one stream flow counter-currently?

No. That changes the boundary-value problem and requires a different integration strategy.

How do I use the Three stream parallel heat exchanger outlet temperatures calculator?

Enter Stream 1 heat-capacity rate (W/K), Stream 2 heat-capacity rate (W/K), Stream 3 heat-capacity rate (W/K), Total stream 1 to 2 conductance (W/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Three stream parallel heat exchanger outlet temperatures?

Stream 1 heat-capacity rate (W/K) = 1000; Stream 2 heat-capacity rate (W/K) = 800; Stream 3 heat-capacity rate (W/K) = 1200; Total stream 1 to 2 conductance (W/K) = 500; Total stream 1 to 3 conductance (W/K) = 300; Total stream 2 to 3 conductance (W/K) = 200; Stream 1 inlet temperature (°C) = 100; Stream 2 inlet temperature (°C) = 20; Stream 3 inlet temperature (°C) = 40. Stream 1 outlet temperature: 67.803995 °C Stream 2 outlet temperature: 48.440284 °C Stream 3 outlet temperature: 47.869815 °C Total stream energy residual: 8.73114914e-11 W Three parallel streams enter at 100, 20 and 40 °C with capacity rates 1,000, 800 and 1,200 W/K.