How to use this calculator
Check whether one actuator can independently influence both states of a linear plant.
- Enter A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s), A22 (1/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Two state actuator controllability explained
Test whether one actuator can reach both states of a two-state linear system, then inspect how strongly reachable directions depend on the units used for each state.
How the calculation works
C=[B,AB]. det(C)≠0 gives full two-state controllability; singular values quantify sensitivity to the chosen state scaling.
Build the reachability matrix from the actuator vector and its image under A. Interpret small singular values only after choosing meaningful state scales.
Set up the calculation
a— A11 (1/s)- First row, first column of the state matrix.
b— A12 (state 1/state 2/s)- Contribution of state two to the time derivative of state one.
c— A21 (state 2/state 1/s)- Coupling from the first state into the second derivative.
d— A22 (1/s)- Second row, second column of the state matrix.
g— B1 (state 1/input/s)- First component of the actuator input vector.
j— B2 (state 2/input/s)- Second component of the actuator input vector.
Limits of this model
A near-zero determinant needs conditioning analysis, not a universal absolute pass/fail tolerance. This test does not include actuator limits.
Check this example
A11 (1/s) = 0; A12 (state 1/state 2/s) = 1; A21 (state 2/state 1/s) = -2; A22 (1/s) = -3; B1 (state 1/input/s) = 0; B2 (state 2/input/s) = 1.
- Controllability determinant: -1 mixed state units
- Smallest singular value: 0.302776 scaled state units
- Largest singular value: 3.302776 scaled state units
With B=(0,1) in the default coupled model, the direct and propagated actuator directions span both state coordinates.
Reading the outputs
The determinant tests exact rank; singular values show direction strength in the units and scaling entered.
Frequently asked questions
Does controllable mean easy to control?
No. Required effort can still be large.
Do unit changes affect the singular values?
Yes; state scaling changes numerical conditioning.
Is a stable plant always controllable?
No. Stability and actuator reachability are different properties.
How do I use the Two state actuator controllability calculator?
Enter A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s), A22 (1/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Two state actuator controllability?
A11 (1/s) = 0; A12 (state 1/state 2/s) = 1; A21 (state 2/state 1/s) = -2; A22 (1/s) = -3; B1 (state 1/input/s) = 0; B2 (state 2/input/s) = 1. Controllability determinant: -1 mixed state units Smallest singular value: 0.302776 scaled state units Largest singular value: 3.302776 scaled state units With B=(0,1) in the default coupled model, the direct and propagated actuator directions span both state coordinates.