Two state feedback pole placement calculator

Design full-state feedback gains for a controllable two-state plant and two chosen real closed-loop poles.

4,000 tools
Two state feedback pole placement calculator — A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s) and calculation method
Two state feedback pole placement calculator: inputs and calculation method.

How to use this calculator

Design full-state feedback gains for a controllable two-state plant and two chosen real closed-loop poles.

  1. Enter A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s), A22 (1/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Two state feedback pole placement explained

For the negative-feedback convention u = −Kx, the selected gains make the characteristic polynomial of A−BK equal to (s−p)(s−q). A reachable single-input pair is required; the gain values depend on the state and input scaling.

Feedback gain K1: 18 input/state 1 in the worked scenario.

Inputs, symbols, and units

a — A11 (1/s)
First row, first column of the state matrix.
b — A12 (state 1/state 2/s)
Contribution of state two to the time derivative of state one.
c — A21 (state 2/state 1/s)
Coupling from the first state into the second derivative.
d — A22 (1/s)
Second row, second column of the state matrix.
g — B1 (state 1/input/s)
First component of the actuator input vector.
j — B2 (state 2/input/s)
Second component of the actuator input vector.
p — Desired real pole 1 (1/s)
First desired eigenvalue of A−BK.
q — Desired real pole 2 (1/s)
Second desired real eigenvalue; may equal the first.

Formula and method

u=−Kx; K=[0,1][B,AB]⁻¹[A²−(p+q)A+pqI]. Desired characteristic polynomial is (s−p)(s−q).

The negative-feedback convention is built into u=−Kx. State availability is assumed; pole placement does not select gains for noise or actuator constraints.

A worked scenario

A11 (1/s) = 0; A12 (state 1/state 2/s) = 1; A21 (state 2/state 1/s) = -2; A22 (1/s) = -3; B1 (state 1/input/s) = 0; B2 (state 2/input/s) = 1; Desired real pole 1 (1/s) = -4; Desired real pole 2 (1/s) = -5.

  • Feedback gain K1: 18 input/state 1
  • Feedback gain K2: 6 input/state 2
  • Closed-loop trace: -9 1/s

Move the default plant poles from −1 and −2 to −4 and −5 using both state measurements.

Assumptions and edge cases

Only a single actuator and two real target poles are supported. A singular reachability matrix is rejected.

Reading the outputs

K1 and K2 multiply the first and second states respectively; trace provides a simple pole-sum check.

Frequently asked questions

May a gain be negative?

Yes; its sign depends on state and actuator conventions.

Can poles be repeated?

The analytic single-input formula permits repeated real target poles.

Do faster poles always help?

No. They can increase control effort and sensitivity to unmodeled dynamics.

How do I use the Two state feedback pole placement calculator?

Enter A11 (1/s), A12 (state 1/state 2/s), A21 (state 2/state 1/s), A22 (1/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Two state feedback pole placement?

A11 (1/s) = 0; A12 (state 1/state 2/s) = 1; A21 (state 2/state 1/s) = -2; A22 (1/s) = -3; B1 (state 1/input/s) = 0; B2 (state 2/input/s) = 1; Desired real pole 1 (1/s) = -4; Desired real pole 2 (1/s) = -5. Feedback gain K1: 18 input/state 1 Feedback gain K2: 6 input/state 2 Closed-loop trace: -9 1/s Move the default plant poles from −1 and −2 to −4 and −5 using both state measurements.