How to use this calculator
Estimate UV dose when average irradiance stays constant over a measured exposure interval.
- Enter Average UV irradiance (mW/cm²), Exposure time (seconds). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
A UV dose is the light intensity accumulated over time. For a constant average irradiance, multiply that intensity by the exposure duration to convert the measurement into energy per unit area.
Inputs and units
irradiance— Average UV irradiance (mW/cm²)- Average irradiance at the target plane during exposure.
time— Exposure time (seconds)- Duration for which the average irradiance applies.
Formula
D (mJ/cm²) = I (mW/cm²) × t (s); D (J/m²) = 10 × D (mJ/cm²). For changing intensity, dose is the time integral of irradiance.
Method
The calculator assumes the entered average irradiance is constant during the interval. It reports dose in millijoules per square centimeter and joules per square meter using the exact area-unit conversion.
Worked example
An average irradiance of 1.2 mW/cm² for 30 seconds gives 36 mJ/cm², equivalent to 360 J/m².
Assumptions and limits
This calculation is an ideal fluence estimate from entered irradiance and time. It does not account for shadowing, absorption, source spectrum, distance-dependent intensity, organism sensitivity, or reactor dose distribution. It is not a validation or safety determination for water treatment, disinfection, or exposure limits.
Frequently asked questions
Why does mW/cm² times seconds give mJ/cm²?
A milliwatt is a millijoule per second, so multiplying by seconds gives millijoules per square centimeter.
What if irradiance changes during exposure?
Use the time-averaged irradiance for a simple estimate or integrate measured irradiance over time for a varying source.
Does the calculated dose prove that water is disinfected?
No. A validated reactor assessment must consider UV transmittance, hydraulics, intensity distribution, target organisms, and required dose.
How do I use the UV dose from irradiance and exposure time calculator?
Enter Average UV irradiance (mW/cm²), Exposure time (seconds). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of UV dose from irradiance and exposure time?
An average irradiance of 1.2 mW/cm² for 30 seconds gives 36 mJ/cm², equivalent to 360 J/m².
Reference: U.S. EPA public water-system planning guidance. See our calculation methodology.