CalcWorldHub
Free online calculator · no signup

Van der Pauw Sheet Resistance Calculator

Solve the van der Pauw relation for sheet resistance and bulk resistivity from two four-probe resistance measurements.

4,000 tools
Van der Pauw Sheet Resistance Calculator — Characteristic resistance, RA (Ω), Characteristic resistance, RB (Ω), Sample thickness (µm) and calculation method
Van der Pauw Sheet Resistance Calculator: inputs and calculation method.

How to use this calculator

Solve the van der Pauw relation for sheet resistance and bulk resistivity from two four-probe resistance measurements.

  1. Enter Characteristic resistance, RA (Ω), Characteristic resistance, RB (Ω), Sample thickness (µm). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Electronics calculation

How this calculation works

The van der Pauw method obtains sheet resistance for a thin, uniform sample with four small contacts around its perimeter. Two characteristic resistance measurements determine sheet resistance through an implicit equation, which is solved here by bounded bisection.

Inputs and units

resistanceA — Characteristic resistance, RA (Ω)
One of the two characteristic four-terminal resistance measurements.
resistanceB — Characteristic resistance, RB (Ω)
The second characteristic four-terminal resistance measurement.
thicknessUm — Sample thickness (µm)
Uniform sample thickness used to convert sheet resistance to bulk resistivity.

Formula

Displayed formula

exp(−πRA/RS) + exp(−πRB/RS) = 1; ρ = RS t.

Method

Enter positive resistance measurements RA and RB in ohms and sample thickness in micrometres. The calculator solves for RS and multiplies by thickness to report bulk resistivity in Ω·m and Ω·cm.

Worked example

For RA = 100 Ω, RB = 120 Ω, and thickness = 500 µm, bisection gives sheet resistance ≈497.12846 Ω/□ and bulk resistivity ≈0.248564 Ω·m (24.8564 Ω·cm).

Assumptions and limits

The standard method assumes a uniform, isotropic, simply connected thin sample with small peripheral contacts and suitable reciprocal measurements. This numerical estimate does not validate contact placement, symmetry, anisotropy, sample geometry, or measurement uncertainty.

Frequently asked questions

Why is the solution numerical?

For unequal RA and RB, the van der Pauw equation is implicit in sheet resistance and has no simple closed-form inverse.

What if the two measurements are equal?

The solution reduces to RS = πR/ln(2).

What sample conditions are assumed?

The classical theorem assumes a uniform, thin, simply connected sample with small contacts on its boundary.

How do I use the Van der Pauw Sheet Resistance Calculator?

Enter Characteristic resistance, RA (Ω), Characteristic resistance, RB (Ω), Sample thickness (µm). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Van der Pauw Sheet Resistance?

For RA = 100 Ω, RB = 120 Ω, and thickness = 500 µm, bisection gives sheet resistance ≈497.12846 Ω/□ and bulk resistivity ≈0.248564 Ω·m (24.8564 Ω·cm).