How to use this calculator
Estimate photodiode current from incident optical power, device responsivity, and dark current.
- Enter Incident optical power (µW), Responsivity (A/W), Dark current (µA). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Photodiode responsivity relates the current generated by light to optical power at the detector. This tool converts the optical power in microwatts and responsivity in amperes per watt into photocurrent in microamperes, then adds a user-entered dark-current value for a simple total-current estimate.
Inputs and units
power— Incident optical power (µW)- Optical power reaching the active photodiode area.
responsivity— Responsivity (A/W)- Photocurrent per incident optical watt at the relevant wavelength.
dark— Dark current (µA)- Current offset to add when estimating total current.
Formula
Photocurrent (µA) = optical power (µW) × responsivity (A/W). Estimated total current = photocurrent + dark current.
Method
Enter optical power incident on the active detector, the responsivity at the relevant wavelength and operating conditions, and dark current in microamperes.
Worked example
With 50 µW incident power and responsivity 0.55 A/W, estimated photocurrent is 27.5 µA. Adding 0.02 µA dark current gives 27.52 µA total.
Assumptions and limits
The calculation assumes a linear responsivity at the chosen wavelength and operating point. It omits amplifier loading, bias dependence, temperature variation, spectral integration, and noise. Use detector datasheet conditions for design.
Frequently asked questions
Where does responsivity come from?
Use the detector datasheet value at the relevant wavelength, bias, and temperature.
Does this include amplifier output voltage?
No. It estimates detector current only; transimpedance gain and loading are not modeled.
Why separate photocurrent and dark current?
Photocurrent is caused by incident light, while dark current is present without illumination.
How do I use the Photodiode photocurrent calculator?
Enter Incident optical power (µW), Responsivity (A/W), Dark current (µA). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Photodiode photocurrent?
With 50 µW incident power and responsivity 0.55 A/W, estimated photocurrent is 27.5 µA. Adding 0.02 µA dark current gives 27.52 µA total.
Reference: Hamamatsu Photonics detector-responsivity technical note. See our calculation methodology.