How to use this calculator
Screen proximity to saturated pool-boiling burnout using a hydrodynamic large-horizontal-surface estimate.
- Enter Latent heat (J/kg), Saturated vapor density (kg/m³), Saturated liquid density (kg/m³), Surface tension (N/m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Zuber large-surface pool boiling crisis estimate explained
The Zuber relation estimates hydrodynamic critical heat flux for saturated pool boiling from vapor generation and surface-tension scaling.
How the calculation works
q″CHF=0.131 hfg ρv^0.5[σg(ρl−ρv)]^0.25.
Use saturated properties at the actual operating pressure. The ratio to applied heat flux is a model comparison, not a guaranteed equipment safety factor.
Set up the calculation
latent— Latent heat (J/kg)- Latent heat (J/kg). Enter the value for this state; the units shown are used without an unstated conversion.
rv— Saturated vapor density (kg/m³)- Saturated vapor density (kg/m³). Enter the value for this state; the units shown are used without an unstated conversion.
rl— Saturated liquid density (kg/m³)- Saturated liquid density (kg/m³). Enter the value for this state; the units shown are used without an unstated conversion.
sig— Surface tension (N/m)- Surface tension (N/m). Enter the value for this state; the units shown are used without an unstated conversion.
applied— Applied heat flux for comparison (W/m²)- Applied heat flux for comparison (W/m²). Enter the value for this state; the units shown are used without an unstated conversion.
A— Horizontal heated area (m²)- Horizontal heated area (m²). Enter the value for this state; the units shown are used without an unstated conversion.
Limits of this model
Large upward-facing horizontal surface, saturated pool, no forced flow, subcooling, confinement, orientation correction or surface enhancement. Real crisis limits can differ substantially.
Check this example
Latent heat (J/kg) = 2257000; Saturated vapor density (kg/m³) = 0.6; Saturated liquid density (kg/m³) = 958; Surface tension (N/m) = 0.059; Applied heat flux for comparison (W/m²) = 100000; Horizontal heated area (m²) = 0.01.
- Hydrodynamic critical heat flux estimate: 1111079.174602 W/m²
- Estimated CHF / applied heat flux: 11.110792
- Estimated area heat rate at CHF: 11110.791746 W
The entered saturated water-like properties give a Zuber critical heat flux estimate of 1.11108 MW/m². Compared with 100,000 W/m² applied, the ratio is 11.1108; this ideal large-surface screening ratio is not a certified heater safety factor.
Reading the outputs
Critical flux and corresponding area heat rate are estimates; CHF/applied is dimensionless.
Frequently asked questions
Is CHF the same as the onset of nucleate boiling?
No. CHF is the high-flux crisis where vapor removal can no longer sustain the nucleate regime.
Can this certify a heater safe?
No. Geometry, transients, surface condition and required margins need equipment-specific verification.
Does this predict film-boiling temperature?
No. It only estimates the peak saturated nucleate-pool heat flux.
How do I use the Zuber large-surface pool boiling crisis estimate calculator?
Enter Latent heat (J/kg), Saturated vapor density (kg/m³), Saturated liquid density (kg/m³), Surface tension (N/m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Zuber large-surface pool boiling crisis estimate?
Latent heat (J/kg) = 2257000; Saturated vapor density (kg/m³) = 0.6; Saturated liquid density (kg/m³) = 958; Surface tension (N/m) = 0.059; Applied heat flux for comparison (W/m²) = 100000; Horizontal heated area (m²) = 0.01. Hydrodynamic critical heat flux estimate: 1111079.174602 W/m² Estimated CHF / applied heat flux: 11.110792 Estimated area heat rate at CHF: 11110.791746 W The entered saturated water-like properties give a Zuber critical heat flux estimate of 1.11108 MW/m². Compared with 100,000 W/m² applied, the ratio is 11.1108; this ideal large-surface screening ratio is not a certified heater safety factor.
Background or definition reference: IIT NPTEL boiling-regime and CHF module.
Primary source: N. Zuber, Hydrodynamic Aspects of Boiling Heat Transfer (1959), archived by UNT Libraries; the thesis derives critical heat flux from hydrodynamic limits for boiling.
Read our calculation methodology.