Select coefficients for one substance and convention
The calculator fields are Antoine coefficient A, Antoine coefficient B (K), Antoine coefficient C (K), Temperature (K), and coefficient lower and upper validity limits (K). The equation used here is log₁₀(P in bar) = A − B/(T + C). Coefficients are not interchangeable across publications: they depend on the source’s pressure unit, temperature scale, logarithm convention, and fitted interval.
For the default water example, the coefficient set corresponds to pressure in bar and temperature in kelvin over the stated 273–303 K interval. NIST presents several water coefficient ranges with different constants and, in some records, other pressure units. Copy all constants and their range from the same row; do not combine A from one fit with B or C from another.
Evaluate the logarithmic form
First calculate T + C, then divide B by that denominator, subtract the quotient from A, and raise ten to the result: P = 10^[A − B/(T + C)]. The logarithm’s base is 10, not the natural logarithm. The output is an estimated saturation vapor pressure in bar; converting bar to another pressure unit is a separate unit conversion.
The reciprocal denominator explains why a wrong temperature convention can change the answer substantially. Celsius-based Antoine constants require Celsius inputs and the exact convention stated by their source; this calculator expects kelvin in its temperature field. A numerical temperature of 25 entered as 25 K is not equivalent to room temperature, and replacing K with °C without changing coefficients is invalid.
Respect the validity interval
A fitted correlation is intended for a stated temperature range. The calculator checks that the lower limit is below the upper limit and that the entered temperature lies within the supplied interval, with a nonzero T + C denominator. Passing those checks establishes only that the values are internally admissible; it does not prove that the coefficients are correct for the chosen substance.
Do not extend the fit across a phase transition or far beyond its tabulated temperatures simply because the equation returns a number. The relevant phase and pressure conditions matter, and different coefficient rows can cover different ranges. For mixtures, vapor composition and activity effects require a mixture model; a pure-component saturation pressure is not a mixture bubble-point calculation.
Calculate vapor pressure with a matched coefficient set
Enter A, B, C, T, and the coefficient validity endpoints from one documented data row. Keep B and C in kelvin-compatible units and enter T in kelvin. The calculator outputs the pressure in bar according to its embedded formula. Record the source, substance, coefficient range, and the date or version of the data consulted when you use the value in a report.
A hand check should reproduce the intermediate exponent before evaluating the power of ten. This catches a common parenthesis error: A − B/(T + C) is not (A − B)/(T + C). Compare the final order of magnitude with a trusted property reference, especially if the result will drive equipment selection or a safety assessment.
Worked examples
Water at 298.15 K
Inputs: A = 5.40221; B = 1838.675 K; C = −31.737 K; T = 298.15 K; range = 273–303 K
Calculation: P = 10^[5.40221 − 1838.675/(298.15 − 31.737)]
P = 0.0316674874 bar, or 3.16674874 kPa.
Water at 293.15 K with the same set
Inputs: A = 5.40221; B = 1838.675 K; C = −31.737 K; T = 293.15 K; range = 273–303 K
Calculation: P = 10^[5.40221 − 1838.675/(293.15 − 31.737)]
P = 0.0233672712 bar; the lower temperature gives a lower saturation pressure for this same-phase interval.
Interpret saturation pressure carefully
Saturation pressure is the equilibrium vapor pressure over a pure liquid or solid at a specified temperature. It is not automatically the system’s total pressure, a partial pressure in a flowing process, or a boiling temperature. At a given external pressure, boiling behavior requires comparing that pressure with the appropriate saturation condition while accounting for the actual system.
The result inherits the fitted data’s limits and uncertainty. For design use, consult the underlying source and relevant standards, confirm the species and phase, and use a validated thermodynamic method when the application demands it. This calculator is a transparent correlation evaluation, not a substitute for property verification or process-safety review.