How to use this calculator
Evaluate a vapor-pressure correlation while checking the entered coefficient temperature interval.
- Enter Antoine coefficient A, Antoine coefficient B (K), Antoine coefficient C (K), Temperature (K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Antoine vapor pressure explained
The Antoine equation estimates a substance’s saturation vapor pressure from empirical coefficients and temperature. The coefficient set is valid only over its stated temperature range and pressure unit.
Inputs, symbols, and units
a— Antoine coefficient A- Antoine coefficient A.
b— Antoine coefficient B (K)- Antoine coefficient B (K).
c— Antoine coefficient C (K)- Antoine coefficient C (K).
t— Temperature (K)- Temperature (K).
lo— Coefficient lower validity limit (K)- Coefficient lower validity limit (K).
hi— Coefficient upper validity limit (K)- Coefficient upper validity limit (K).
Formula and method
pow(10,a-b/(t+c))
Symbols use the input definitions below. Uses log10(P in bar)=A−B/(T in kelvin+C).
A worked scenario
Antoine coefficient A = 5.40221; Antoine coefficient B (K) = 1838.675; Antoine coefficient C (K) = -31.737; Temperature (K) = 298.15; Coefficient lower validity limit (K) = 273; Coefficient upper validity limit (K) = 303.
- Saturation vapor pressure: 0.03166749 bar
This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Assumptions and edge cases
Uses log10(P in bar)=A−B/(T in kelvin+C). Defaults are NIST water coefficients valid from 273 to 303 K.
Frequently asked questions
Can I enter Celsius coefficients?
Not without converting their full convention.
Why is a validity range required?
Extrapolation can produce misleading pressures.
Is this mixture vapor pressure?
No, it is a pure-component correlation.
How do I use the Antoine vapor pressure calculator?
Enter Antoine coefficient A, Antoine coefficient B (K), Antoine coefficient C (K), Temperature (K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Antoine vapor pressure?
Antoine coefficient A = 5.40221; Antoine coefficient B (K) = 1838.675; Antoine coefficient C (K) = -31.737; Temperature (K) = 298.15; Coefficient lower validity limit (K) = 273; Coefficient upper validity limit (K) = 303. Saturation vapor pressure: 0.03166749 bar This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Method reference: NIST Chemistry WebBook: water Antoine coefficients.
Read our calculation methodology.