CalcWorldHub
Free online calculator · no signup

Clausius Clapeyron vapor pressure shift calculator

Estimate saturation pressure at another temperature from one reference pressure and vaporization enthalpy.

4,000 tools
Clausius Clapeyron vapor pressure shift calculator — Known saturation pressure (kPa), Known temperature (K), Target temperature (K) and calculation method
Clausius Clapeyron vapor pressure shift calculator: inputs and calculation method.

How to use this calculator

Estimate saturation pressure at another temperature from one reference pressure and vaporization enthalpy.

  1. Enter Known saturation pressure (kPa), Known temperature (K), Target temperature (K), Molar enthalpy of vaporization (kJ/mol). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Clausius Clapeyron vapor pressure shift explained

Clausius Clapeyron vapor pressure shift6.2477kPa
Clausius Clapeyron vapor pressure shift: 6.247721 kPa in the worked scenario.

How the calculation works

p*exp(-l*1000/8.31446261815324*(1/s-1/t))

Ideal vapor, negligible liquid volume, and constant vaporization enthalpy are assumed..

Set up the calculation

p — Known saturation pressure (kPa)
Known saturation vapor pressure at the reference temperature, in kPa.
t — Known temperature (K)
Reference saturation temperature in Kelvin.
s — Target temperature (K)
Target temperature in Kelvin at which pressure is estimated.
l — Molar enthalpy of vaporization (kJ/mol)
Molar enthalpy of vaporization in kJ/mol, treated as constant across the temperature interval.

Limits of this model

Ideal vapor, negligible liquid volume, and constant vaporization enthalpy are assumed.

Check this example

Known saturation pressure (kPa) = 3.17; Known temperature (K) = 298.15; Target temperature (K) = 310; Molar enthalpy of vaporization (kJ/mol) = 44.

  • Clausius Clapeyron vapor pressure shift: 6.247721 kPa

Reading the outputs

The result estimates saturation vapor pressure at the target temperature while holding enthalpy of vaporization constant. For a positive latent heat, raising the temperature raises the estimated pressure; accuracy falls when the constant-latent-heat approximation spans a wide interval.

Frequently asked questions

Can I use it near the critical point?

The approximations become poor there.

Is this an Antoine fit?

No, it uses a thermodynamic two-temperature approximation.

Must pressures be absolute?

Yes.

How do I use the Clausius Clapeyron vapor pressure shift calculator?

Enter Known saturation pressure (kPa), Known temperature (K), Target temperature (K), Molar enthalpy of vaporization (kJ/mol). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Clausius Clapeyron vapor pressure shift?

Known saturation pressure (kPa) = 3.17; Known temperature (K) = 298.15; Target temperature (K) = 310; Molar enthalpy of vaporization (kJ/mol) = 44. Clausius Clapeyron vapor pressure shift: 6.247721 kPa