CalcWorldHub
Chemistry · CalcWorldHub

Arrhenius Rate Constant: Compare Reaction Rates by Temperature

The Arrhenius equation estimates how a rate constant depends on absolute temperature: k = A exp(−Ea/RT). With A = 1.0 × 10¹⁰ s⁻¹, Ea = 50 kJ/mol, and T = 300 K, k is about 1.97 × 10¹ s⁻¹. The result is meaningful only when A’s units match the reaction-order convention and the model fits the reaction over the temperature range.

Open calculator
A reaction flask, temperature indicator, and rising rate curve show how temperature influences a reaction-rate coefficient.

Share this article

The Arrhenius rate constant equals pre-exponential factor times the exponential of negative activation energy over RT.
Convert activation energy to joules per mole when using R in SI units.

Read the three calculator inputs

The inputs are Pre-exponential factor A (s⁻¹), Activation energy Ea (kJ/mol), and Temperature (K). The calculator requires A > 0, Ea ≥ 0, and T > 0. The label gives first-order units for A; for reactions of another order, the rate-constant and pre-exponential-factor units depend on the concentration convention and must be interpreted accordingly.

Use kelvin, not Celsius, because absolute temperature appears in the denominator of the exponential. Convert energy consistently: the calculator multiplies Ea in kJ/mol by 1000 to obtain J/mol and uses R = 8.314462618 J mol⁻¹ K⁻¹. A value that was already entered in joules would therefore be scaled incorrectly by a factor of one thousand.

Understand the exponential relation

The original Arrhenius form is k = A exp(−Ea/(RT)). A sets the scale, while the exponential term expresses the temperature dependence associated with Ea. For positive Ea, increasing T makes the exponent less negative and usually increases k; lowering T makes it more negative. The change is nonlinear, so equal temperature increments do not imply equal rate-constant increments.

Take natural logarithms to obtain ln(k) = ln(A) − Ea/(RT). If A and Ea are held constant, plotting ln(k) against 1/T yields a line with slope −Ea/R. This transformed view is useful for checking a model against several measurements, but the calculator evaluates one parameter set and does not perform a fit or estimate uncertainty.

Check parameters before using the output

The pre-exponential factor is not a universal constant for a chemical family; it belongs with the specified reaction model and has the same units as k. For a complex or multistep reaction, the observed rate law may not correspond to one elementary step. Do not copy A and Ea from a different reaction, catalyst, phase, or unit convention merely because the substance names look similar.

The simple Arrhenius relation assumes a stable parameterization over the temperature range of interest. Modified forms may include a temperature exponent, and some systems show curvature or mechanism changes. The calculator’s finite-number check protects against invalid arithmetic, not against selecting parameters outside the experiment or literature range from which they were obtained.

Calculate a rate constant from Arrhenius parameters

Enter A, Ea, and T in the units printed beside each field. The calculator computes A × exp[−Ea × 1000/(8.314462618 × T)] and displays the result to five decimal places in scientific-aware formatting. If the result is outside the supported floating-point range, the page asks you to check the inputs rather than presenting an invalid value.

For a manual check, evaluate the dimensionless ratio Ea/(RT) after converting Ea to joules per mole, take its negative exponential, and multiply by A. The exponent must be dimensionless. Preserve the rate constant’s unit from A; the calculator result does not independently infer or convert between first- and higher-order rate laws.

Worked examples

Evaluate at 300 K

Inputs: A = 1.0 × 10¹⁰ s⁻¹; Ea = 50 kJ/mol; T = 300 K

Calculation: k = 1.0 × 10¹⁰ exp[−50,000/(8.314462618 × 300)]

k = 19.696844 s⁻¹ (about 1.970 × 10¹ s⁻¹).

A second temperature and parameter set

Inputs: A = 2.0 × 10⁸ s⁻¹; Ea = 35 kJ/mol; T = 325 K

Calculation: k = 2.0 × 10⁸ exp[−35,000/(8.314462618 × 325)]

k = 4.74101037 × 10² s⁻¹; compare only with values using the same reaction and units.

Pre-exponential factor, activation energy, and kelvin temperature feed into the Arrhenius exponential to produce a rate constant.
Keep each parameter tied to the same reaction model.

Compare temperatures without claiming more than the model

When A and Ea stay fixed, the ratio between temperatures T2 and T1 is k2/k1 = exp[(Ea/R)(1/T1 − 1/T2)]. This is a useful scenario comparison because A cancels. It also shows why temperature conversion errors matter: reciprocal kelvin changes enter inside an exponential. A small input error can be magnified when Ea is large or the comparison spans a broad range.

For reporting, state the reaction, rate-law order, A with units, Ea, temperature, and parameter source. Compare predicted values with measurements where possible. An Arrhenius calculation is a model-based estimate of a rate coefficient, not a complete prediction of reaction time, yield, safety, or process performance; those outcomes also depend on concentrations, transport, and the reaction network.

Sources and further reading

Share this article

Browse all articles · Calculator: Arrhenius rate constant calculator