Choose the area or fixture branch
Enter bathroom floor area in square feet. For an area at or below 100 ft², the calculator returns the same number as CFM. Above 100 ft², it stops using area and counts toilets, showers, standard bathtubs, and jetted tubs. Each toilet, shower, or standard tub contributes 50 CFM; each jetted tub contributes 100 CFM.
The switch at 100 ft² is part of this calculator's method. In the larger-room branch, set the fixture counts served by the exhaust system. If a tub has jets, count it in the jetted-tub field rather than also counting it as a standard tub. Rooms above 100 ft² need at least one fixture entered or the calculator rejects the input.
Worked examples
The examples show both formula branches and the calculator's CFM-to-metric conversion.
An 80 ft² bathroom uses the area branch
Inputs: Bathroom area = 80 ft²; toilets = 1; showers = 1; standard tubs = 1; jetted tubs = 0.
Calculation: Because 80 ≤ 100, airflow = 80 CFM; metric conversion = 80 × 1.699 = 135.92 m³/h.
The calculator returns 80 CFM without adding fixture values in this area branch.
A 120 ft² bathroom uses fixture counts
Inputs: Bathroom area = 120 ft²; toilets = 1; showers = 1; standard tubs = 0; jetted tubs = 1.
Calculation: Because 120 > 100, airflow = 50 × (1 + 1 + 0) + 100 × 1 = 200 CFM; metric conversion = 200 × 1.699 = 339.8 m³/h.
The fixture branch gives 200 CFM. The jetted tub contributes 100 CFM and is not also counted as a standard tub.
Understand the two equations
For a small or medium room, required CFM = floor area in ft². For a larger room, required CFM = 50 × (toilets + showers + standard tubs) + 100 × jetted tubs. The result is also converted to approximate cubic metres per hour using 1 CFM ≈ 1.699 m³/h. CFM is a rate of air volume, not a room volume or a count of air changes.
HVI publications differ on small-room intermittent sizing: its Bathroom Ventilation page gives 1 CFM per square foot up to 100 ft², while its Home Ventilation Guide states a 50 CFM minimum below 100 ft²; another HVI page lists 50 CFM for bathrooms 50 ft² and smaller. This calculator uses only area, so 40 ft² returns 40 CFM. Apply the recommendation and locally adopted code that match the operating mode; the runtime does not enforce a universal minimum.
Compare a rating with delivered airflow
A fan's published CFM rating describes a stated test condition. A long duct, several elbows, a restrictive grille, a dirty screen, or a poorly sized termination can reduce the airflow delivered after installation. HVI's guidance and residential-code provisions discuss ventilation rates, but the selected fan must still be capable of moving the required air through the actual duct system.
Check the product's performance curve or certified rating at the system resistance that applies to your installation. A higher nominal fan rating is not a substitute for correct ducting, a clear outdoor termination, and a route for replacement air to enter the room. The calculator has no fields for static pressure, duct diameter, equivalent length, sound level, or makeup-air path.
Treat exhaust as an operating system
Moisture control depends on where the exhaust is drawn, how long it runs, and whether replacement air can flow into the bathroom. HVI recommends locating exhaust near the shower or tub where appropriate and allowing makeup air to enter. A timer or other control can keep the fan operating after use; follow the chosen fan's instructions and the locally adopted building requirements.
The calculator does not estimate humidity removal, surface condensation, noise, or the time needed to dry a particular room. Steam rooms, enclosed toilet rooms, unusually high ceilings, and complex duct runs may need separate design attention. Use a qualified installer for code questions, electrical work, or a system that is not clearing moisture as expected.
Keep the result tied to the room definition
Measure the floor area of the space the fan is intended to serve, and decide which fixtures share the exhaust path. Two bathrooms connected to separate fans should not have their fixture counts combined as if one fan serves both. Conversely, a central exhaust system may serve multiple rooms, but its design requires more than this single-room estimate.
Use consistent units and round the shopping choice only after checking actual product ratings. The metric output is a conversion of the CFM value, not a second independent recommendation. Requirements can vary by code edition, jurisdiction, and whether ventilation is intermittent or continuous, so verify the applicable rule for the project.