A battery state of health capacity calculation compares a battery’s measured full-charge capacity with its original rated capacity. It reports a percentage and the amp-hour difference from the rating, making capacity fade easier to describe without implying a complete safety or remaining-life diagnosis. The ratio is meaningful only when the test conditions are understood.

Open calculator
A battery health report compares rated and measured amp-hour capacity and displays the percentage alongside the absolute difference.

Share this article

Measured full-charge amp-hours are divided by the rated amp-hour capacity to calculate a percentage.
State of health here describes capacity only.

Choose comparable capacity values

Enter rated capacity in Ah from the product documentation and measured full-charge capacity in Ah from a controlled test. The two values should refer to the same battery or pack boundary and use a compatible charge/discharge procedure. A measurement from a different cutoff voltage, current, temperature, or rest interval may not be comparable with the rating.

Both fields must be nonnegative and the rated capacity must be greater than zero. The tool allows a measured value above the rating; it does not cap state of health at 100%. That can happen because of measurement tolerance, a conservative nameplate rating, or differing test conditions. Investigate the test before treating a value above 100% as an improvement in every aspect of battery health.

Calculate a capacity-based indicator

The formula is SOH (%) = measured full-charge capacity ÷ rated capacity × 100. The capacity difference is rated capacity − measured capacity. If a 100 Ah battery now measures 82 Ah, the ratio is 82% and the difference is 18 Ah. A positive difference means the measured capacity is below the original rating; a negative difference means the measured result is higher.

Capacity is one measurable dimension, not a complete health score. The output does not evaluate internal resistance, peak power, self-discharge, cell imbalance, protection faults, cycle life, or physical condition. NREL performance testing treats usable energy and state of charge as measured performance metrics; the data must be collected with a defined protocol before the ratio can support a comparison.

Keep the test procedure visible

Record the charging endpoint, rest period, discharge current, temperature, and cutoff voltage with each capacity result. A battery tested at a high rate can deliver fewer amp-hours before its voltage cutoff than the same unit at a gentle rate. Mixing a datasheet value measured under one rate with a field test under another can make a calculation arithmetically correct but interpretively misleading.

Use a consistent unit and system boundary. If the rated value applies to a single cell string but the measured value covers a parallel pack, convert both to the same scope first. Do not compare a pack’s estimated usable energy with a cell’s full-charge Ah rating; voltage and the allowed state-of-charge window are different quantities from capacity in amp-hours.

Read the percentage and difference together

The percentage gives a scale-independent ratio, while the Ah difference preserves the absolute capacity change. An 18 Ah loss is substantial for a 100 Ah battery but much less for a 1,000 Ah installation. The calculator reports both to two decimal places and also repeats the measured capacity, so retain the original test value when you save a maintenance record.

A 90 Ah rating with 76.5 Ah measured gives 85% state of health and a 13.5 Ah shortfall. The proportion matches the first example, but the absolute lost capacity differs. When comparing a fleet, group tests by chemistry, size, and test method; a single percentage can conceal important differences in duty cycle or discharge conditions.

Worked examples

Measured capacity below rating

Inputs: Rated capacity 100 Ah; measured full-charge capacity 82 Ah.

Calculation: SOH = 82 ÷ 100 × 100 = 82%; difference = 100 − 82 = 18 Ah.

Capacity-based SOH is 82.00%, with an 18.00 Ah shortfall.

A smaller battery measured consistently

Inputs: Rated capacity 90 Ah; measured full-charge capacity 76.5 Ah.

Calculation: SOH = 76.5 ÷ 90 × 100 = 85%; difference = 90 − 76.5 = 13.5 Ah.

The measured capacity is 85.00% of rating and 13.50 Ah below it.

A battery capacity test shows charge, rest, controlled discharge current, and cutoff voltage as conditions for a repeatable measurement.
A capacity percentage depends on how the test was run.

Use the result within its limits

Capacity-based SOH is not a prediction of how many months remain or how many cycles are left. Battery aging may affect capacity, resistance, voltage response, and safety in different ways. A pack can still meet a capacity threshold while having a separate fault, and a measured capacity shortfall does not by itself identify its cause.

Use the result as a traceable capacity comparison and follow the manufacturer’s testing and service instructions. If the value is used for warranty, asset replacement, or safety decisions, rely on the applicable test procedure and qualified review. The calculator performs a ratio; it does not certify a battery or replace diagnostics.

Sources and further reading