Use matching power measurements
Enter heating output in kW and electrical input in kW. Heating output must be nonnegative, and electrical input must be positive. If one value is in Btu/h or watts, convert it to kilowatts first so the ratio compares like units. Do not combine a full-system heat output with compressor-only input unless that boundary is intentional.
COP heating = heat output ÷ electrical input. When both are power rates, kW divided by kW is dimensionless. A COP of 4 means the equipment delivers four units of heat for each unit of electrical work at the stated condition; the extra heat is moved from the source rather than created by electrical resistance.
Know the condition behind a COP
Heating COP changes with outdoor temperature, indoor supply temperature, airflow, defrost, compressor speed, and auxiliary resistance heat. A laboratory or manufacturer rating is tied to a test condition. Do not treat a value from mild weather as the expected COP in a cold design condition or during a defrost cycle.
The calculator uses up to four decimal places for its result and retains the entered powers to four decimals in the displayed equation. Extra digits describe the arithmetic precision only. For equipment comparison, use ratings tested at comparable temperatures, water or air flow, and system boundaries rather than comparing numbers collected under different conditions. Record whether the test includes indoor fans, circulation pumps, and controls; those auxiliary loads can change the system-level ratio.
Compare output with electrical input
At 8 kW heating output and 2 kW electrical input, COP is 4.0. At 12.5 kW output and 3.2 kW input, it is 3.90625, displayed as 3.9063. Both ratios exceed one because a heat pump transfers heat from a source; they are not efficiency percentages bounded by 100%.
The denominator should include the electrical loads relevant to your question. If fans, pumps, controls, or backup resistance heaters are outside the measurement boundary, the calculated ratio will exclude them. Use system-level input to describe system-level performance or clearly label a compressor-only ratio.
Worked examples
Mild-condition heating check
Inputs: Heating output 8 kW; electrical input 2 kW.
Calculation: Heating COP = 8 ÷ 2 = 4.
The point COP is 4 for the stated operating condition.
Higher output under a different condition
Inputs: Heating output 12.5 kW; electrical input 3.2 kW.
Calculation: Heating COP = 12.5 ÷ 3.2 = 3.90625, displayed as 3.9063.
The four-decimal maximum display is 3.9063; compare it only with a matching test condition.
Distinguish COP from seasonal ratings
A point COP describes one operating condition. Seasonal metrics aggregate performance across a prescribed range of temperatures, cycling, and test methods. DOE documentation distinguishes COP, EER, SEER, and other metrics and notes that their conditions and units differ. Do not multiply a single COP by annual hours to estimate seasonal energy without modeling load and operating conditions.
Heating COP also differs from cooling COP, even for reversible equipment. The useful output is heat delivered in heating mode or heat removed in cooling mode. Keep the mode and test boundary in the report. A single number that omits mode, temperature, and auxiliary heat can be difficult to compare or reproduce.
Use the calculation as a check
The ratio can verify a measured test or explain a manufacturer’s steady-state value when its inputs are available. It does not size the heat pump, predict room temperature, estimate annual cost, or determine whether a system meets a building load. Those decisions require weather, equipment curves, distribution losses, controls, and electricity tariffs.
Use the result with the equipment data sheet and test conditions. If the COP seems unexpectedly low or high, confirm units and measurement boundaries before changing the inputs. A coefficient of performance is a useful performance ratio, not a safety approval or a guarantee of household energy savings.