CalcWorldHub
Electronics · CalcWorldHub

Shockley Diode with Series Resistance: Current and Voltage

A diode in series with a resistor does not have one fixed forward voltage: current and junction voltage must satisfy both the exponential junction law and the resistor drop. With a 1.0 V source, 100 Ω resistor, 1 pA saturation current, ideality factor 1.8, and 300 K junction, this model solves approximately 0.5969 mA and 0.9403 V across the junction.

Open calculator
A forward diode’s exponential current-voltage curve is paired with a series resistor and marked bias point.

Share this article

A forward source drives a diode through a series resistor, with the diode voltage and current marked at the operating point.
The current is set by the intersection of the diode relation and the resistor load line.

Solve the diode and resistor together

Kirchhoff’s voltage law gives Vs = IR + Vd. The Shockley forward relation is I = Is[exp(Vd/(nVT)) − 1], where VT = kT/q. Combining them yields Vs = IR + nVT ln(1 + I/Is). The calculator solves this implicit equation numerically because current appears both outside and inside the logarithm.

Vs is the nonnegative forward supply in volts, R is series resistance in ohms, Is is positive saturation current in amperes, n is a dimensionless ideality factor, and T is absolute junction temperature in kelvin. The tool reports forward current, junction voltage Vs − IR, and incremental diode resistance nVT/(I + Is).

Use saturation current at the entered temperature

The saturation current is not a universal constant for a diode. It depends strongly on device construction and temperature. Enter a value that corresponds to the selected diode model and the temperature field; the calculator does not convert Is from one temperature to another or infer it from a part number.

The built-in thermal voltage is kT/q, using the exact Boltzmann constant and elementary charge in the runtime. At 300 K it is about 25.85 mV. The factor n scales the junction’s logarithmic voltage for a given current ratio. A fitted ideality factor and Is can vary across current ranges, so treat the pair as model parameters, not generic silicon constants.

Solve two forward operating points

For Vs = 1.0 V, R = 100 Ω, Is = 1 × 10⁻¹² A, n = 1.8, and T = 300 K, numerical solution gives I ≈ 0.596863 mA. The resistor drop is about 59.686 mV, leaving Vd ≈ 0.940314 V. Substituting the current into both terms recovers the 1.0 V supply within numerical precision.

With Vs = 2.0 V, R = 330 Ω, Is = 2 nA, n = 1.5, and T = 350 K, the solution is about 4.069205 mA. The resistor drop is 1.342838 V and the junction has about 0.657162 V. The larger current is consistent with the higher supply; the lower junction drop reflects the different Is, n, and temperature assumptions, not a fixed-voltage rule.

Worked examples

One-volt source with a 100 ohm limiter

Inputs: Vs = 1.0 V, R = 100 Ω, Is = 1 pA, n = 1.8, T = 300 K.

Calculation: At I ≈ 0.596863 mA, IR ≈ 0.059686 V and Vd ≈ 0.940314 V; n(kT/q)ln(1 + I/Is) ≈ 0.940314 V, so IR + Vd ≈ 1.000000 V.

The self-consistent current is about 0.597 mA; the incremental diode resistance at that point is about 77.96 Ω.

Higher supply with a warmer diode model

Inputs: Vs = 2.0 V, R = 330 Ω, Is = 2 nA, n = 1.5, T = 350 K.

Calculation: The numerical root is I ≈ 4.069205 mA; IR ≈ 1.342838 V, leaving Vd ≈ 0.657162 V. The local resistance n(kT/q)/(I + Is) is about 11.118 Ω.

Most of the supply is dropped across the external resistor at this operating point; the junction voltage follows the entered exponential model.

An exponential diode current-voltage curve has a tangent line at a marked DC operating point.
Incremental diode resistance describes the local tangent, not a large-signal replacement.

Interpret the incremental resistance carefully

The reported small-signal resistance is the local slope around the computed DC point, not the external resistor and not the total series resistance. In the first example it is about 77.96 Ω; in the second it is about 11.12 Ω. The value changes with current and temperature because it is inversely related to I + Is.

This incremental quantity is useful for a small perturbation near the bias point. It does not mean the diode can be replaced by that resistor for a large voltage swing. For a signal analysis, combine the local junction resistance with the external circuit around the same DC operating point and keep the signal small enough for the linear approximation.

Avoid common input and model errors

Do not enter milliamperes in a field that expects amperes: 1 mA is 0.001 A. Likewise, Is is often many orders smaller than operating current, so check whether a datasheet gives amperes or microamperes and preserve the scale. Temperature is Kelvin; 27 °C is about 300.15 K, not 27 K.

A very small Is can make the diode voltage seem plausible at one current while producing a large change at another. Forward voltage must be interpreted together with the current and the model fit. The runtime assumes a positive series resistance, nonnegative supply, positive Is, positive n, and positive T; it does not model reverse breakdown or a negative-supply operating state.

Check the model against a device curve

For a practical check, use the diode’s forward I–V curve at the relevant junction temperature. From the solved current, estimate the external resistor drop IR and subtract it from the supply; the remaining voltage should be consistent with the curve. If not, verify Is, n, temperature, and whether the plotted curve includes package or lead resistance.

This is a forward DC approximation. It excludes reverse recovery, junction capacitance, self-heating feedback, recombination changes across operating regions, and breakdown. Use a compact model or measured curve for switching behavior or thermal analysis, and retain the source and temperature associated with any extracted Is value.

Sources and further reading

Share this article

Browse all articles · Calculator: Shockley diode with series resistance calculator